Endovascular stent-graft placement for the treatment of acute aortic dissection.
New England Journal of Medicine 1999 May 21
BACKGROUND: The standard treatment for acute aortic dissection is either surgical or medical therapy, depending on the morphologic features of the lesion and any associated complications. Irrespective of the form of treatment, the associated mortality and morbidity are considerable.
METHODS: We studied the placement of endovascular stent-grafts across the primary entry tear for the management of acute aortic dissection originating in the descending thoracic aorta. We evaluated the feasibility, safety, and effectiveness of transluminal stent-graft placement over the entry tear in 4 patients with acute type A aortic dissections (which involve the ascending aorta) and 15 patients with acute type B aortic dissections (which are confined to the descending aorta). Dissections involved aortic branches in 14 of the 19 patients (74 percent), and symptomatic compromise of multiple branch vessels was observed in 7 patients (37 percent). The stent-grafts were made of self-expanding stainless-steel covered with woven polyester or polytetrafluoroethylene material.
RESULTS: Placement of endovascular stent-grafts across the primary entry tears was technically successful in all 19 patients. Complete thrombosis of the thoracic aortic false lumen was achieved in 15 patients (79 percent), and partial thrombosis was achieved in 4 (21 percent). Revascularization of ischemic branch vessels, with subsequent relief of corresponding symptoms, occurred in 76 percent of the obstructed branches. Three of the 19 patients died within 30 days, for an early mortality rate of 16 percent (95 percent confidence interval, 0 to 32 percent). There were no deaths and no instances of aneurysm or aortic rupture during the subsequent average follow-up period of 13 months.
CONCLUSIONS: These initial results suggest that stent-graft coverage of the primary entry tear may be a promising new treatment for selected patients with acute aortic dissection. This technique requires further evaluation, however, to assess its therapeutic potential fully.
METHODS: We studied the placement of endovascular stent-grafts across the primary entry tear for the management of acute aortic dissection originating in the descending thoracic aorta. We evaluated the feasibility, safety, and effectiveness of transluminal stent-graft placement over the entry tear in 4 patients with acute type A aortic dissections (which involve the ascending aorta) and 15 patients with acute type B aortic dissections (which are confined to the descending aorta). Dissections involved aortic branches in 14 of the 19 patients (74 percent), and symptomatic compromise of multiple branch vessels was observed in 7 patients (37 percent). The stent-grafts were made of self-expanding stainless-steel covered with woven polyester or polytetrafluoroethylene material.
RESULTS: Placement of endovascular stent-grafts across the primary entry tears was technically successful in all 19 patients. Complete thrombosis of the thoracic aortic false lumen was achieved in 15 patients (79 percent), and partial thrombosis was achieved in 4 (21 percent). Revascularization of ischemic branch vessels, with subsequent relief of corresponding symptoms, occurred in 76 percent of the obstructed branches. Three of the 19 patients died within 30 days, for an early mortality rate of 16 percent (95 percent confidence interval, 0 to 32 percent). There were no deaths and no instances of aneurysm or aortic rupture during the subsequent average follow-up period of 13 months.
CONCLUSIONS: These initial results suggest that stent-graft coverage of the primary entry tear may be a promising new treatment for selected patients with acute aortic dissection. This technique requires further evaluation, however, to assess its therapeutic potential fully.
Full text links
Related Resources
Trending Papers
Consensus Statement on Vitamin D Status Assessment and Supplementation: Whys, Whens, and Hows.Endocrine Reviews 2024 April 28
The Tricuspid Valve: A Review of Pathology, Imaging, and Current Treatment Options: A Scientific Statement From the American Heart Association.Circulation 2024 April 26
British Society of Gastroenterology guidelines for the management of hepatocellular carcinoma in adults.Gut 2024 April 17
Interstitial Lung Disease: A Review.JAMA 2024 April 23
Ventilator Waveforms May Give Clues to Expiratory Muscle Activity.American Journal of Respiratory and Critical Care Medicine 2024 April 25
Systemic lupus erythematosus.Lancet 2024 April 18
Acute Kidney Injury and Electrolyte Imbalances Caused by Dapagliflozin Short-Term Use.Pharmaceuticals 2024 March 27
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app