COMPARATIVE STUDY
JOURNAL ARTICLE
Combined posterior chamber phakic intraocular lens and laser in situ keratomileusis: bioptics for extreme myopia.
Journal of Refractive Surgery 1999 May
PURPOSE: To examine the efficacy, predictability, stability, and safety of combined posterior chamber phakic intraocular lens (IOL) implantation and laser in situ keratomileusis (LASIK) in eyes with extreme myopia.
METHODS: We analyzed the results of 67 eyes that received a posterior chamber hydrogel-collagen plate phakic IOL (STAAR Collamer Implantable Contact Lens) and also underwent secondary LASIK for the correction of extreme myopia. Mean follow-up was 3 months after the LASIK portion of the procedure (range, 1 day to 6 mo after LASIK).
RESULTS: Mean preoperative spherical equivalent refraction was -23.00 +/- 3.60 D (range, -18.75 to -35.00 D), and mean refractive cylinder was 1.50 +/- 1.20 D (range, 0 to 5.00 D). Mean spherical equivalent refraction after IOL implantation and before LASIK was -6.00 +/- 2.80 D (range, -2.00 to -14.38 D) and mean refractive cylinder 1.50 +/- 1.10 D (range, 0 to 5.00 D). Mean postoperative spherical equivalent refraction at last examination after the LASIK portion of the two-part phakic IOL-LASIK procedure was -0.20 +/- 0.90 D (range, +1.75 to -5.13 D), and mean refractive cylinder was 0.50 +/- 0.50 (range, 0 to 2.25 D). Eighty-five percent (57 eyes) were within +/- 1.00 D and 67% (45 eyes) were within +/- 0.50 D of emmetropia at last examination. The refractions remained stable with a statistically insignificant change (P > .05 at each interval) during follow-up. Postoperative uncorrected visual acuity at last examination was 20/20 or better in 3% (2 eyes) and 20/40 or better in 69% (46 eyes). A gain of 2 or more lines of spectacle-corrected visual acuity was seen in 51 eyes (76%) and no eyes lost 2 or more lines of spectacle-corrected visual acuity at last examination.
CONCLUSION: Combined posterior chamber phakic IOL implantation with the STAAR Collamer plate lens and LASIK (bioptics) is an effective and reasonably predictable method for correcting myopia from -18 to -35 D. Gains in spectacle-corrected visual acuity were common, and results demonstrated good short-term safety and refractive stability.
METHODS: We analyzed the results of 67 eyes that received a posterior chamber hydrogel-collagen plate phakic IOL (STAAR Collamer Implantable Contact Lens) and also underwent secondary LASIK for the correction of extreme myopia. Mean follow-up was 3 months after the LASIK portion of the procedure (range, 1 day to 6 mo after LASIK).
RESULTS: Mean preoperative spherical equivalent refraction was -23.00 +/- 3.60 D (range, -18.75 to -35.00 D), and mean refractive cylinder was 1.50 +/- 1.20 D (range, 0 to 5.00 D). Mean spherical equivalent refraction after IOL implantation and before LASIK was -6.00 +/- 2.80 D (range, -2.00 to -14.38 D) and mean refractive cylinder 1.50 +/- 1.10 D (range, 0 to 5.00 D). Mean postoperative spherical equivalent refraction at last examination after the LASIK portion of the two-part phakic IOL-LASIK procedure was -0.20 +/- 0.90 D (range, +1.75 to -5.13 D), and mean refractive cylinder was 0.50 +/- 0.50 (range, 0 to 2.25 D). Eighty-five percent (57 eyes) were within +/- 1.00 D and 67% (45 eyes) were within +/- 0.50 D of emmetropia at last examination. The refractions remained stable with a statistically insignificant change (P > .05 at each interval) during follow-up. Postoperative uncorrected visual acuity at last examination was 20/20 or better in 3% (2 eyes) and 20/40 or better in 69% (46 eyes). A gain of 2 or more lines of spectacle-corrected visual acuity was seen in 51 eyes (76%) and no eyes lost 2 or more lines of spectacle-corrected visual acuity at last examination.
CONCLUSION: Combined posterior chamber phakic IOL implantation with the STAAR Collamer plate lens and LASIK (bioptics) is an effective and reasonably predictable method for correcting myopia from -18 to -35 D. Gains in spectacle-corrected visual acuity were common, and results demonstrated good short-term safety and refractive stability.
Full text links
Related Resources
Trending Papers
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app