Photorefractive keratectomy with an ablatable mask for myopic astigmatism.
Journal of Refractive Surgery 1999 September
PURPOSE: To evaluate efficacy, safety, and stability of photoastigmatic keratectomy (PARK) carried out with a Summit Apex Plus laser using an ablatable mask.
METHODS: Forty-one eyes of 41 patients with myopic astigmatism with follow-up of 12 months were evaluated. Treatment efficacy was compared in groups with high (>6.00 D) versus low (< or =6.00 D) preoperative spherical equivalent subjective manifest refraction, in groups with high (>2.00 D) versus low (< or =2.00 D) preoperative cylindrical component and in groups divided according to preoperative axis of cylinder.
RESULTS: At 12 months after surgery, mean spherical equivalent manifest refraction in all 41 eyes was -0.30 +/- 0.90 D. Mean cylinder component was 0.60 +/- 0.70 D. Mean reduction in astigmatic component was 67 +/- 47%. Uncorrected visual acuity of 0.5 or more was achieved in 79% of eyes; 71% of eyes achieved 0.8 or more. At 1 month after surgery, 49% of eyes had a loss of 2 or more lines of spectacle-corrected visual acuity. This loss was restored at 12 months. No statistically significant differences were found between the different subgroups.
CONCLUSION: Photoastigmatic keratectomy with ablatable mask gives satisfactory results. No relation in efficacy was found when taking into account the amount of preoperative spherical component, the cylindrical component, or the cylinder axis direction.
METHODS: Forty-one eyes of 41 patients with myopic astigmatism with follow-up of 12 months were evaluated. Treatment efficacy was compared in groups with high (>6.00 D) versus low (< or =6.00 D) preoperative spherical equivalent subjective manifest refraction, in groups with high (>2.00 D) versus low (< or =2.00 D) preoperative cylindrical component and in groups divided according to preoperative axis of cylinder.
RESULTS: At 12 months after surgery, mean spherical equivalent manifest refraction in all 41 eyes was -0.30 +/- 0.90 D. Mean cylinder component was 0.60 +/- 0.70 D. Mean reduction in astigmatic component was 67 +/- 47%. Uncorrected visual acuity of 0.5 or more was achieved in 79% of eyes; 71% of eyes achieved 0.8 or more. At 1 month after surgery, 49% of eyes had a loss of 2 or more lines of spectacle-corrected visual acuity. This loss was restored at 12 months. No statistically significant differences were found between the different subgroups.
CONCLUSION: Photoastigmatic keratectomy with ablatable mask gives satisfactory results. No relation in efficacy was found when taking into account the amount of preoperative spherical component, the cylindrical component, or the cylinder axis direction.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app