Long-term outcomes after carotid stent placement treatment of carotid artery dissection.

Neurosurgery 1999 December
OBJECTIVE: To assess the long-term outcomes after stent placement for the treatment of carotid artery dissections.

METHODS: Between 1992 and 1998, seven patients underwent stenting procedures for treatment of extracranial carotid artery dissections resulting from various causes, including trauma (n = 2), iatrogenesis (n = 2), spontaneous development (n = 2), and fibromuscular dysplasia (n = 1). Stenting procedures were performed for large, nonhealing, dissection-induced pseudoaneurysms (four cases) or severe preocclusive stenosis (three cases). A total of 11 stents were placed (Palmaz stents, n = 8; Wallstents, n = 3). Radiological follow-up examinations were performed after a mean period of 17.7 months (range, 1-67 mo), using conventional or computed tomographic angiography. Clinical follow-up data were obtained after a mean period of 42.9 months (range, 13-72 mo).

RESULTS: All stent placements resulted in complete resolution of dissection-induced stenosis. For two of the four patients with aneurysms, the lesions occluded spontaneously at the time of the procedure. The third patient required coil embolization of the pseudoaneurysm. One patient exhibited progressive shrinkage of the aneurysm in serial follow-up examinations, with healing after 18 months. No clinical complications were associated with the procedures. One patient exhibited progression to asymptomatic occlusion 3 months after stenting. The remaining six patients exhibited no significant changes in luminal diameters. All patients remained in clinically stable condition, with no ischemic symptoms, during more than 3.5 years (mean period) of follow-up monitoring.

CONCLUSION: This experience suggests that stents placed for treatment of extracranial carotid artery dissections remain patent and patients remain free of symptoms on a long-term basis. Additional studies will be required to determine the optimal types of stents and intervals for follow-up monitoring using imaging.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app