We have located links that may give you full text access.
CLINICAL TRIAL
JOURNAL ARTICLE
MULTICENTER STUDY
Noninvasive diagnosis by Doppler ultrasonography of fetal anemia due to maternal red-cell alloimmunization. Collaborative Group for Doppler Assessment of the Blood Velocity in Anemic Fetuses.
New England Journal of Medicine 2000 January 7
BACKGROUND: Invasive techniques such as amniocentesis and cordocentesis are used for diagnosis and treatment in fetuses at risk for anemia due to maternal red-cell alloimmunization. The purpose of our study was to determine the value of noninvasive measurements of the velocity of blood flow in the fetal middle cerebral artery for the diagnosis of fetal anemia.
METHODS: We measured the hemoglobin concentration in blood obtained by cordocentesis and also the peak velocity of systolic blood flow in the middle cerebral artery in 111 fetuses at risk for anemia due to maternal red-cell alloimmunization. Peak systolic velocity was measured by Doppler velocimetry. To identify the fetuses with anemia, the hemoglobin values of those at risk were compared with the values in 265 normal fetuses.
RESULTS: Fetal hemoglobin concentrations increased with increasing gestational age in the 265 normal fetuses. Among the 111 fetuses at risk for anemia, 41 fetuses did not have anemia; 35 had mild anemia; 4 had moderate anemia; and 31, including 12 with hydrops, had severe anemia. The sensitivity of an increased peak velocity of systolic blood flow in the middle cerebral artery for the prediction of moderate or severe anemia was 100 percent either in the presence or in the absence of hydrops (95 percent confidence interval, 86 to 100 percent for the 23 fetuses without hydrops), with a false positive rate of 12 percent.
CONCLUSIONS: In fetuses without hydrops that are at risk because of maternal red-cell alloimmunization, moderate and severe anemia can be detected noninvasively by Doppler ultrasonography on the basis of an increase in the peak velocity of systolic blood flow in the middle cerebral artery.
METHODS: We measured the hemoglobin concentration in blood obtained by cordocentesis and also the peak velocity of systolic blood flow in the middle cerebral artery in 111 fetuses at risk for anemia due to maternal red-cell alloimmunization. Peak systolic velocity was measured by Doppler velocimetry. To identify the fetuses with anemia, the hemoglobin values of those at risk were compared with the values in 265 normal fetuses.
RESULTS: Fetal hemoglobin concentrations increased with increasing gestational age in the 265 normal fetuses. Among the 111 fetuses at risk for anemia, 41 fetuses did not have anemia; 35 had mild anemia; 4 had moderate anemia; and 31, including 12 with hydrops, had severe anemia. The sensitivity of an increased peak velocity of systolic blood flow in the middle cerebral artery for the prediction of moderate or severe anemia was 100 percent either in the presence or in the absence of hydrops (95 percent confidence interval, 86 to 100 percent for the 23 fetuses without hydrops), with a false positive rate of 12 percent.
CONCLUSIONS: In fetuses without hydrops that are at risk because of maternal red-cell alloimmunization, moderate and severe anemia can be detected noninvasively by Doppler ultrasonography on the basis of an increase in the peak velocity of systolic blood flow in the middle cerebral artery.
Full text links
Trending Papers
A Personalized Approach to the Management of Congestion in Acute Heart Failure.Heart International 2023
Potential Mechanisms of the Protective Effects of the Cardiometabolic Drugs Type-2 Sodium-Glucose Transporter Inhibitors and Glucagon-like Peptide-1 Receptor Agonists in Heart Failure.International Journal of Molecular Sciences 2024 Februrary 21
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app