We have located links that may give you full text access.
Journal Article
Multicenter Study
Research Support, Non-U.S. Gov't
Lung nodule enhancement at CT: multicenter study.
Radiology 2000 January
PURPOSE: To test the hypothesis that absence of statistically significant lung nodule enhancement (< or =15 HU) at computed tomography (CT) is strongly predictive of benignity.
MATERIALS AND METHODS: Five hundred fifty lung nodules were studied. Of these, 356 met all entrance criteria and had a diagnosis. On nonenhanced, thin-section CT scans, the nodules were solid, 5-40 mm in diameter, relatively spherical, homogeneous, and without calcification or fat. All patients were examined with 3-mm-collimation CT before and after intravenous injection of contrast material. CT scans through the nodule were obtained at 1, 2, 3, and 4 minutes after the onset of injection. Peak net nodule enhancement and time-attenuation curves were analyzed. Seven centers participated.
RESULTS: The prevalence of malignancy was 48% (171 of 356 nodules). Malignant neoplasms enhanced (median, 38.1 HU; range, 14.0-165.3 HU) significantly more than granulomas and benign neoplasms (median, 10.0 HU; range, -20.0 to 96.0 HU; P < .001). With 15 HU as the threshold, the sensitivity was 98% (167 of 171 malignant nodules), the specificity was 58% (107 of 185 benign nodules), and the accuracy was 77% (274 of 356 nodules).
CONCLUSION: Absence of significant lung nodule enhancement (< or = 15 HU) at CT is strongly predictive of benignity.
MATERIALS AND METHODS: Five hundred fifty lung nodules were studied. Of these, 356 met all entrance criteria and had a diagnosis. On nonenhanced, thin-section CT scans, the nodules were solid, 5-40 mm in diameter, relatively spherical, homogeneous, and without calcification or fat. All patients were examined with 3-mm-collimation CT before and after intravenous injection of contrast material. CT scans through the nodule were obtained at 1, 2, 3, and 4 minutes after the onset of injection. Peak net nodule enhancement and time-attenuation curves were analyzed. Seven centers participated.
RESULTS: The prevalence of malignancy was 48% (171 of 356 nodules). Malignant neoplasms enhanced (median, 38.1 HU; range, 14.0-165.3 HU) significantly more than granulomas and benign neoplasms (median, 10.0 HU; range, -20.0 to 96.0 HU; P < .001). With 15 HU as the threshold, the sensitivity was 98% (167 of 171 malignant nodules), the specificity was 58% (107 of 185 benign nodules), and the accuracy was 77% (274 of 356 nodules).
CONCLUSION: Absence of significant lung nodule enhancement (< or = 15 HU) at CT is strongly predictive of benignity.
Full text links
Related Resources
Trending Papers
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Prevention and treatment of ischaemic and haemorrhagic stroke in people with diabetes mellitus: a focus on glucose control and comorbidities.Diabetologia 2024 April 17
British Society for Rheumatology guideline on management of adult and juvenile onset Sjögren disease.Rheumatology 2024 April 17
Diagnosis and Management of Cardiac Sarcoidosis: A Scientific Statement From the American Heart Association.Circulation 2024 April 19
Albumin: a comprehensive review and practical guideline for clinical use.European Journal of Clinical Pharmacology 2024 April 13
Eosinophilic Esophagitis: Clinical Pearls for Primary Care Providers and Gastroenterologists.Mayo Clinic Proceedings 2024 April
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app