Journal Article
Research Support, U.S. Gov't, P.H.S.
Add like
Add dislike
Add to saved papers

Imaging pulmonary emboli and deep venous thrombi with 99mTc-bitistatin, a platelet-binding polypeptide from viper venom.

UNLABELLED: An imaging test that could locate both pulmonary emboli (PE) and their source, active deep venous thrombi (DVT), would be valuable in patient management. Bitistatin, an 83-amino-acid polypeptide isolated from Bitis arietans venom, binds avidly to the glycoprotein IIb/IIIa receptor on platelets. The goal of this study was to label bitistatin with 99mTc and assess its potential for imaging thrombi and emboli in vivo.

METHODS: Molecular modeling of bitistatin indicated that its primary amines are located on the opposite side of the molecule from the receptor-binding domain. The primary amines were reacted with succinimidyl-4-hydrazino nicotinate hydrochloride to place 2.4 hydrazino nicotinate (Hn) chelating groups per peptide molecule. Hn-bitistatin was labeled by incubation with 99mTc-glucoheptonate to 96 TBq/mmol and then tested for binding to platelets in vitro and for imaging of 24-h-old DVT and PE in a canine model used previously for other thrombus tracers.

RESULTS: 99mTc-Hn-bitistatin bound to stimulated platelets with a dissociation constant (Kd) = 32 nmol/L, similar to that of 125I-bitistatin (Kd = 41 nmol/L). In vivo, focal uptake was observed in planar images as early as 30 min (DVT) and 60 min (PE) after injection. Lesion uptake of 99mTc-Hn-bitistatin at 4 h after injection was calculated in terms of percentage injected dose per gram (%ID/g) of tissue and averaged 0.89 %ID/g PE and 0.79 %ID/g DVT. Lesion-to-background ratios averaged 34:1 (PE-to-lung), 18:1 (DVT-to-blood), and 284:1 (DVT-to-muscle). These values were not significantly different from iodinated bitistatin, but uptakes were higher than other tracers tested in the same model.

CONCLUSION: 99mTc-Hn-bitistatin retains the functional activity of the iodinated peptide, has higher DVT and PE uptakes than other thrombus tracers in this standardized model, and has target-to-background characteristics suitable for imaging both PE and DVT in a single test.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app