We have located links that may give you full text access.
Transthoracic three-dimensional echocardiography in the preoperative assessment of atrioventricular septal defect morphology.
American Journal of Cardiology 2000 March 2
A prospective study of 3-dimensional (3-D) transthoracic echocardiographic definition of atrioventricular septal defect (AVSD) morphology and its dynamic changes during the cardiac cycle was performed. The information obtained from 2-D and 3-D transthoracic echocardiography (TTE) was compared with intraoperative findings in an unselected group of 15 patients with AVSD (median age 22 months). In all study patients, 3-D reconstructions provided anatomic views of the atrioventricular valve(s) en face from either atrial or ventricular perspectives that allowed comprehensive assessment of dynamic valve morphology and the mechanism of valve reflux. Left-sided valve function was correctly assessed by 2-D TTE in 11 of 15 patients (73%) and in 14 of 15 (93%) by 3-D TTE. In 6 of 15 patients (40%), the severity of right-sided valve reflux was described precisely by 2-D TTE and in 12 of 15 patients (80%) by 3-D TTE. Additionally, 3-D TTE supplemented the diagnostic information to that available from 2-D TTE on atrial and ventricular septal defects. Although primum atrial septal defects were depicted by 2-D and 3-D TTE in all 15 patients, the description of defect size was more precise by the 3-D TTE (80% vs. 100%, respectively). The presence of secundum atrial septal defect was correctly diagnosed by both TTE techniques in 10 of 15 patients. Disagreement regarding the size of the defect was present only in 2 of 10 patients by 2-D TTE. In another 2 patients, 3-D TTE described multiple defect fenestrations that were missed by 2-D TTE. Thus, the agreement score was 73% for 2-D and 100% for 3-D echo. The agreement for the presence and sizing of ventricular septal defects was 67% for 2-D and 93% for 3-D echo. We conclude that 3-D TTE provided accurate anatomic reconstructions of the common atrioventricular junction and that the use of dynamic 3-D TTE enhanced the anatomic diagnostic capability of standard 2-D TTE. Medica, Inc.
Full text links
Trending Papers
A Personalized Approach to the Management of Congestion in Acute Heart Failure.Heart International 2023
Potential Mechanisms of the Protective Effects of the Cardiometabolic Drugs Type-2 Sodium-Glucose Transporter Inhibitors and Glucagon-like Peptide-1 Receptor Agonists in Heart Failure.International Journal of Molecular Sciences 2024 Februrary 21
The Effect of Albumin Administration in Critically Ill Patients: A Retrospective Single-Center Analysis.Critical Care Medicine 2024 Februrary 8
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app