Proximity of the posterior cruciate ligament insertion to the popliteal artery as a function of the knee flexion angle: implications for posterior cruciate ligament reconstruction.
Arthroscopy 2000 November
PURPOSE: The purpose of this study was to determine if an optimal knee flexion angle existed that would minimize the risk of neurovascular injury from the passage of transtibial hardware during posterior cruciate ligament (PCL) reconstruction.
TYPE OF STUDY: Cadaveric.
MATERIALS AND METHODS: Fourteen fresh-frozen cadaveric knees were mounted in a Plexiglas apparatus that could be set at 5 different knee flexion angles (0 degrees, 45 degrees, 60 degrees, 90 degrees, and 100 degrees ) while joint distention was maintained. Each knee underwent magnetic resonance imaging in the axial and sagittal planes at each of the 5 flexion angles to determine the distance between the PCL tibial insertion and popliteal artery.
RESULTS: The mean distance, over all 5 flexion angles, between the PCL insertion and the popliteal artery in the axial plane was 7.6 mm, whereas the mean distance in the sagittal plane was 7.2 mm. There was a significant increase in distance with progressive flexion in both planes. Maximum mean distances were noted at 100 degrees of flexion in both the axial (9.9 mm) and sagittal (9.3 mm) planes. An artificial line mimicking the path of a transtibial drill passed through the popliteal artery in 10 of 10 cases at the 0 degrees, 45 degrees, 60 degrees, and 90 degrees angles, and in 6 of 10 cases at the 100 degrees angle.
CONCLUSIONS: The results of this study suggest that increasing knee flexion reduces, but does not completely eliminate, the risk of arterial injury during arthroscopic PCL reconstruction.
TYPE OF STUDY: Cadaveric.
MATERIALS AND METHODS: Fourteen fresh-frozen cadaveric knees were mounted in a Plexiglas apparatus that could be set at 5 different knee flexion angles (0 degrees, 45 degrees, 60 degrees, 90 degrees, and 100 degrees ) while joint distention was maintained. Each knee underwent magnetic resonance imaging in the axial and sagittal planes at each of the 5 flexion angles to determine the distance between the PCL tibial insertion and popliteal artery.
RESULTS: The mean distance, over all 5 flexion angles, between the PCL insertion and the popliteal artery in the axial plane was 7.6 mm, whereas the mean distance in the sagittal plane was 7.2 mm. There was a significant increase in distance with progressive flexion in both planes. Maximum mean distances were noted at 100 degrees of flexion in both the axial (9.9 mm) and sagittal (9.3 mm) planes. An artificial line mimicking the path of a transtibial drill passed through the popliteal artery in 10 of 10 cases at the 0 degrees, 45 degrees, 60 degrees, and 90 degrees angles, and in 6 of 10 cases at the 100 degrees angle.
CONCLUSIONS: The results of this study suggest that increasing knee flexion reduces, but does not completely eliminate, the risk of arterial injury during arthroscopic PCL reconstruction.
Full text links
Trending Papers
A Personalized Approach to the Management of Congestion in Acute Heart Failure.Heart International 2023
Potential Mechanisms of the Protective Effects of the Cardiometabolic Drugs Type-2 Sodium-Glucose Transporter Inhibitors and Glucagon-like Peptide-1 Receptor Agonists in Heart Failure.International Journal of Molecular Sciences 2024 Februrary 21
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app