Lack of agreement between central venous pressure and pulmonary capillary wedge pressure in preeclampsia.
OBJECTIVE: To establish if agreement exists between central venous pressure (CVP) and pulmonary capillary wedge pressure (PCWP) measurements in severe hypertension in pregnancy as analyzed by tests of bias, precision, and 95% limits of agreement.
METHODS: In a prospective study, CVP and PCWP data in 30 patients were collected by means of a pulmonary artery catheter from initiation of therapy until delivery. Patients with a diastolic blood pressure of more than 110 mm Hg were included. Correlation and agreement between CVP and PCWP before and after treatment were evaluated.
RESULTS: The correlation coefficient (r) for CVP-PCWP data in 30 untreated patients was r = 0.64 (p = 0.0002) and for 256 pairs of posttreatment data, it was r = 0.53 (p < 0.0001). Linear regression and correlation for each individual patient in 29 patients with more than 3 measurements showed a significant correlation (p < 0.05) in 19 patients (66%). Correlation was poor (p > 0.05) in 10 patients (34%). The mean difference between PCWP and CVP was 3.5 +/- 2.6 mm Hg (limits of agreement: -1.6 to 8.7) in untreated patients. The mean difference between PCWP and CVP for 256 pairs of data derived posttreatment was 4.9 +/- 3.8 mm Hg (limits of agreement: -2.7 to 12. 5).
CONCLUSION: Invasive measurements of CVP and PCWP were found to agree poorly. Until a reliable noninvasive method is available to measure left ventricular preload, PCWP is the measurement of choice when invasive hemodynamic monitoring is necessary in patients with severe preeclampsia.
METHODS: In a prospective study, CVP and PCWP data in 30 patients were collected by means of a pulmonary artery catheter from initiation of therapy until delivery. Patients with a diastolic blood pressure of more than 110 mm Hg were included. Correlation and agreement between CVP and PCWP before and after treatment were evaluated.
RESULTS: The correlation coefficient (r) for CVP-PCWP data in 30 untreated patients was r = 0.64 (p = 0.0002) and for 256 pairs of posttreatment data, it was r = 0.53 (p < 0.0001). Linear regression and correlation for each individual patient in 29 patients with more than 3 measurements showed a significant correlation (p < 0.05) in 19 patients (66%). Correlation was poor (p > 0.05) in 10 patients (34%). The mean difference between PCWP and CVP was 3.5 +/- 2.6 mm Hg (limits of agreement: -1.6 to 8.7) in untreated patients. The mean difference between PCWP and CVP for 256 pairs of data derived posttreatment was 4.9 +/- 3.8 mm Hg (limits of agreement: -2.7 to 12. 5).
CONCLUSION: Invasive measurements of CVP and PCWP were found to agree poorly. Until a reliable noninvasive method is available to measure left ventricular preload, PCWP is the measurement of choice when invasive hemodynamic monitoring is necessary in patients with severe preeclampsia.
Full text links
Trending Papers
A Personalized Approach to the Management of Congestion in Acute Heart Failure.Heart International 2023
Potential Mechanisms of the Protective Effects of the Cardiometabolic Drugs Type-2 Sodium-Glucose Transporter Inhibitors and Glucagon-like Peptide-1 Receptor Agonists in Heart Failure.International Journal of Molecular Sciences 2024 Februrary 21
The Effect of Albumin Administration in Critically Ill Patients: A Retrospective Single-Center Analysis.Critical Care Medicine 2024 Februrary 8
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app