The role of the coronoid process in elbow stability. A biomechanical analysis of axial loading.
Journal of Bone and Joint Surgery. American Volume 2000 December
BACKGROUND: The current treatment of coronoid process fractures of the ulna is based on the classification system of Regan and Morrey. We found no biomechanical studies that specifically addressed the role of the coronoid process in elbow stability. In the present investigation, the elbows of cadavera were tested before and after fracture of the coronoid process to assess the stabilizing contribution of the coronoid process under axial loading.
METHODS: Six fresh-frozen cadaveric elbows were tested mechanically. All soft tissue surrounding the elbow, including the skin, was left intact. An axial load compressing the elbow joint was applied along the shaft of the forearm in the sagittal plane. A displacement of fifteen millimeters per minute was applied until a load of 100 newtons was attained. Each elbow was tested in 15, 30, 45, 60, 75, 90, 105, and 120 degrees of flexion. Next, less than 25 percent, 25 to 50 percent, or more than 50 percent of the coronoid process was fractured with an osteotome under radiographic guidance, and the testing was repeated. Each elbow served as its own control, and one elbow was used for two tests; therefore, a total of seven situations were investigated. The difference in displacements between the intact and osteotomized elbows was measured.
RESULTS: There was no significant difference, at any flexion position, in posterior axial displacement between the intact elbows and the elbows in which 50 percent or less of the coronoid process was fractured (type I and type II) (p = 0.43). There were significant differences, across all flexion positions, in posterior axial displacement between the intact elbows and the elbows in which more than 50 percent of the coronoid process was fractured (type III) (p = 0.006). Specimens with a type-III fracture also showed a significant increase in displacement compared with specimens with a type-I or type-II fracture (p = 0.012). Specifically, from 60 to 105 degrees of flexion, a significant increase in posterior translation of up to 2.4 millimeters was found (p<0.05).
CONCLUSIONS: In response to axial load, elbows with a fracture involving more than 50 percent of the coronoid process displace more readily than elbows with a fracture involving 50 percent or less of the coronoid process, especially when the elbow is flexed 60 degrees and beyond.
METHODS: Six fresh-frozen cadaveric elbows were tested mechanically. All soft tissue surrounding the elbow, including the skin, was left intact. An axial load compressing the elbow joint was applied along the shaft of the forearm in the sagittal plane. A displacement of fifteen millimeters per minute was applied until a load of 100 newtons was attained. Each elbow was tested in 15, 30, 45, 60, 75, 90, 105, and 120 degrees of flexion. Next, less than 25 percent, 25 to 50 percent, or more than 50 percent of the coronoid process was fractured with an osteotome under radiographic guidance, and the testing was repeated. Each elbow served as its own control, and one elbow was used for two tests; therefore, a total of seven situations were investigated. The difference in displacements between the intact and osteotomized elbows was measured.
RESULTS: There was no significant difference, at any flexion position, in posterior axial displacement between the intact elbows and the elbows in which 50 percent or less of the coronoid process was fractured (type I and type II) (p = 0.43). There were significant differences, across all flexion positions, in posterior axial displacement between the intact elbows and the elbows in which more than 50 percent of the coronoid process was fractured (type III) (p = 0.006). Specimens with a type-III fracture also showed a significant increase in displacement compared with specimens with a type-I or type-II fracture (p = 0.012). Specifically, from 60 to 105 degrees of flexion, a significant increase in posterior translation of up to 2.4 millimeters was found (p<0.05).
CONCLUSIONS: In response to axial load, elbows with a fracture involving more than 50 percent of the coronoid process displace more readily than elbows with a fracture involving 50 percent or less of the coronoid process, especially when the elbow is flexed 60 degrees and beyond.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Diagnosis and Management of Cardiac Sarcoidosis: A Scientific Statement From the American Heart Association.Circulation 2024 April 19
Essential thrombocythaemia: A contemporary approach with new drugs on the horizon.British Journal of Haematology 2024 April 9
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app