Add like
Add dislike
Add to saved papers

Ultrasonic shear coagulation of main hilar vessels: A 4-year experience of 23 pediatric laparoscopic splenectomies without staples.

BACKGROUND: Ultrasonic shears (LCS) are used increasingly for laparoscopic splenectomy. So far however, all investigators use vascular staplers or clips for section of the main splenic artery and vein.

METHODS: After several trials the authors started to use the ultrasonic triple welding technique in open surgery to occlude major vessels of 5 to 8 mm by 10-mm LCS. In June 1997 the authors introduced triple welding into laparoscopic splenectomy to mobilize the complete spleen by LCS.

RESULTS: There was no hemorrhage in 23 laparoscopic splenectomies performed exclusively by LCS and no complications except 1 port site hernia.

CONCLUSIONS: Laparoscopic splenectomy entirely by reusable LCS without clips and stapler is a safe, simple, and inexpensive technique. Moreover, the policy of "leaving nothing back" is an attractive strategy in endoscopic pediatric surgery.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

Managing Alcohol Withdrawal Syndrome.Annals of Emergency Medicine 2024 March 26

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app