In vivo lung deposition of hollow porous particles from a pressurized metered dose inhaler.
Pharmaceutical Research 2002 March
PURPOSE: PulmoSphere particles are specifically engineered for delivery by the pulmonary route with a hollow and porous morphology, physical diameters < 5 microm, and low tap densities (circa 0.1 g x cm(-3)). Deposition of PulmoSphere particles in the human respiratory tract delivered by pressurized metered dose inhaler (pMDI) was compared with deposition of a conventional micronized drug pMDI formulation.
METHODS: Nine healthy nonsmoking subjects (5 male, 4 female) completed a two-way crossover gamma scintigraphic study, assessing the lung and oropharyngeal depositions of albuterol sulfate, formulated as 99mTc-radiolabeled PulmoSphere particles or micronized particles (Ventolin Evohaler, GlaxoSmithKline, Ltd.) suspended in HFA-134a propellant.
RESULTS: Mean (standard deviation) lung deposition, (% ex-valve dose) was doubled for the PulmoSphere formulation compared with Evohaler pMDI (28.5 (11.3) % vs. 14.5 (8.1) %, P < 0.01), whereas oropharyngeal deposition was reduced (42.6 (9.0) % vs. 72.0 (8.0) %, P < 0.01). Both PulmoSphere and Evohaler pMDIs gave uniform deposition patterns within the lungs.
CONCLUSIONS: These data provided "proof of concept" in vivo for the PulmoSphere technology as a method of improving targeting of drugs to the lower respiratory tract from pMDIs, and suggested that the PulmoSphere technology may also be suitable for the delivery of systemically acting molecules absorbed via the lung.
METHODS: Nine healthy nonsmoking subjects (5 male, 4 female) completed a two-way crossover gamma scintigraphic study, assessing the lung and oropharyngeal depositions of albuterol sulfate, formulated as 99mTc-radiolabeled PulmoSphere particles or micronized particles (Ventolin Evohaler, GlaxoSmithKline, Ltd.) suspended in HFA-134a propellant.
RESULTS: Mean (standard deviation) lung deposition, (% ex-valve dose) was doubled for the PulmoSphere formulation compared with Evohaler pMDI (28.5 (11.3) % vs. 14.5 (8.1) %, P < 0.01), whereas oropharyngeal deposition was reduced (42.6 (9.0) % vs. 72.0 (8.0) %, P < 0.01). Both PulmoSphere and Evohaler pMDIs gave uniform deposition patterns within the lungs.
CONCLUSIONS: These data provided "proof of concept" in vivo for the PulmoSphere technology as a method of improving targeting of drugs to the lower respiratory tract from pMDIs, and suggested that the PulmoSphere technology may also be suitable for the delivery of systemically acting molecules absorbed via the lung.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app