We have located links that may give you full text access.
COMPARATIVE STUDY
JOURNAL ARTICLE
RESEARCH SUPPORT, NON-U.S. GOV'T
RESEARCH SUPPORT, U.S. GOV'T, NON-P.H.S.
Subretinal implantation of semiconductor-based photodiodes: durability of novel implant designs.
Selective degeneration of the retinal photoreceptor layers underlies blindness in retinitis pigmentosa (RP) and other inherited retinal disorders. Because there are no therapies for these patients, we are evaluating the possibility that electrical stimulation delivered to the subretinal space by a microphotodiode array (MPA) could replace, in some aspect, the function of diseased photoreceptors. Early MPA prototypes utilized gold as the electrode material, which gradually dissolved during the postoperative period following subretinal implantation. Here we present the results obtained when different MPA materials were used. Semiconductor-based silicon MPAs (2 mm in diameter; 50 microm in thickness), incorporating iridium/iridium oxide (IrOx) or platinum (Pt) electrodes, were implanted into the subretinal space of the right eye of normal cats with the use of vitreoretinal surgical techniques. Indirect ophthalmoscopy, fundus photography, ganzfeld electroretinography, and histology were used for the evaluation of the implanted retinas postoperatively. Infrared (IR) stimulation was used to isolate electrical responses generated by the MPA. The unimplanted left eyes were used for control purposes. After the implantation surgery, subretinal MPAs retained a stable position in the subretinal space. Up to 12 months after surgery, there was little change in the magnitude of the electrical response of IrOx- and Pt-based MPAs to a standard IR light stimulus. Overlying the implant, there was a near-complete loss of the outer retinal layer, which is likely to reflect obstruction of choroidal nourishment to these layers by the solid disk implant. In addition, the inner retinal layers showed variable disorganization. Away from the implant, the retina displayed a normal appearance. In comparison to electroretinograms (ERGs) obtained from unimplanted eyes, responses recorded from implanted eyes had a normal waveform but were slightly smaller in amplitude. These results indicate that IrOx and Pt improve implant electrode durability and that implants incorporating these materials into the electrode layer do not induce panretinal abnormalities.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app