Pulmonary function and exercise response in patients with pectus excavatum after Nuss repair.
Journal of Pediatric Surgery 2003 April
BACKGROUND/PURPOSE: The Ravitch repair of pectus excavatum removes segments of abnormal costal cartilages after which the sternum is elevated and stabilized. Some investigators have found a worsening in total lung capacity postoperatively. Recently, a technique has been used in which the costal cartilages are preserved, and the sternum is elevated with an internal steel bar (Nuss repair). The authors hypothesized that placement of a substernal bar in the first stage of the Nuss repair will not adversely affect pulmonary and exercise function.
METHODS: Patients who presented to the Children's Hospital of Buffalo for surgical repair of pectus excavatum from June 1997 through June 2000 underwent pulmonary function and exercise testing before and 6 to 12 months after the first stage of a Nuss repair.
RESULTS: Ten patients were studied (all boys; mean age at operative repair, 13.4 +/- 3 years). Mean baseline pulmonary function was normal, and no significant differences were seen before and after placement of the intrathoracic bar. Peak oxygen consumption was near normal, although work at VO2max was less than predicted (mean, 68.2% before v. 71.8% after surgery). V(E) was below normal and Vt/FVC was below the expected 50% to 60% level both before and after surgery (41.3% +/- 3 SE and 41.6% +/- 3 SE pre- and postoperatively, respectively).
CONCLUSIONS: Placement of a substernal steel bar in the first stage of the Nuss procedure for repair of pectus excavatum does not cause adverse effects on either static pulmonary function or on the ventilatory response to exercise.
METHODS: Patients who presented to the Children's Hospital of Buffalo for surgical repair of pectus excavatum from June 1997 through June 2000 underwent pulmonary function and exercise testing before and 6 to 12 months after the first stage of a Nuss repair.
RESULTS: Ten patients were studied (all boys; mean age at operative repair, 13.4 +/- 3 years). Mean baseline pulmonary function was normal, and no significant differences were seen before and after placement of the intrathoracic bar. Peak oxygen consumption was near normal, although work at VO2max was less than predicted (mean, 68.2% before v. 71.8% after surgery). V(E) was below normal and Vt/FVC was below the expected 50% to 60% level both before and after surgery (41.3% +/- 3 SE and 41.6% +/- 3 SE pre- and postoperatively, respectively).
CONCLUSIONS: Placement of a substernal steel bar in the first stage of the Nuss procedure for repair of pectus excavatum does not cause adverse effects on either static pulmonary function or on the ventilatory response to exercise.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app