We have located links that may give you full text access.
Comparative Study
Journal Article
Research Support, U.S. Gov't, Non-P.H.S.
Research Support, U.S. Gov't, P.H.S.
Comparative sensitivity of HBV NATs and HBsAg assays for detection of acute HBV infection.
Transfusion 2003 June
BACKGROUND: A study was designed to estimate relative analytic sensitivity and window-period (WP) closure and to project incremental yield of newer HBsAg tests, pooled-sample NAT, and single-sample NAT, compared to currently licensed HBsAg tests.
STUDY DESIGN AND METHODS: HBV DNA and HBsAg test results for 23 HBV seroconversion (SC) panels were first analyzed to construct a model of primary HBV viremia. One-hundred representative samples were then selected from 10 panels and coded with 28 analytical controls. All 128 samples were tested by seven HBsAg tests and by four pooled-sample and three single-sample NAT assay formats. Results were analyzed to obtain differential times to HBV detection and combined with HBV incidence rates to project comparative yields.
RESULTS: HBV doubling time during the ramp-up phase was estimated at 2.56 days. HBsAg concentrations at cutoff for new tests ranged from 0.07 to 0.12 ng per mL, compared with 0.13 to 0.62 ng per mL for licensed tests. Estimated viral load at cutoff ranged from 102 to 267 IU per mL for new tests and from 363 to 1069 IU per mL for licensed tests. HBsAg tests detected 31 to 63 percent of early ramp-up phase samples in the 100-member seroconversion panel study, while pooled-sample NAT detected 55 to 71 percent and single-sample NAT, 82 to 99 percent. Compared with currently licensed HBsAg assays, newer HBsAg assays would reduce the WP by 2 to 9 days; pooled-sample NAT would reduce the WP by 9 to 11 days; and single-sample NAT would reduce the WP by 25 to 36 days.
CONCLUSION: Newer HBsAg tests would be expected to detect an additional 15 to 21 infected units per 107 donations, compared to licensed HBsAg tests. Sensitivity, WP closure, and yield projections for newer HBsAg assays and pooled-sample NAT are comparable. Single-sample NAT would increase yield by 13 to 15 units per 107 donations over pooled-sample NAT and newer HBsAg assays and by 35 to 50 units per 107 donations over currently licensed HBsAg assays.
STUDY DESIGN AND METHODS: HBV DNA and HBsAg test results for 23 HBV seroconversion (SC) panels were first analyzed to construct a model of primary HBV viremia. One-hundred representative samples were then selected from 10 panels and coded with 28 analytical controls. All 128 samples were tested by seven HBsAg tests and by four pooled-sample and three single-sample NAT assay formats. Results were analyzed to obtain differential times to HBV detection and combined with HBV incidence rates to project comparative yields.
RESULTS: HBV doubling time during the ramp-up phase was estimated at 2.56 days. HBsAg concentrations at cutoff for new tests ranged from 0.07 to 0.12 ng per mL, compared with 0.13 to 0.62 ng per mL for licensed tests. Estimated viral load at cutoff ranged from 102 to 267 IU per mL for new tests and from 363 to 1069 IU per mL for licensed tests. HBsAg tests detected 31 to 63 percent of early ramp-up phase samples in the 100-member seroconversion panel study, while pooled-sample NAT detected 55 to 71 percent and single-sample NAT, 82 to 99 percent. Compared with currently licensed HBsAg assays, newer HBsAg assays would reduce the WP by 2 to 9 days; pooled-sample NAT would reduce the WP by 9 to 11 days; and single-sample NAT would reduce the WP by 25 to 36 days.
CONCLUSION: Newer HBsAg tests would be expected to detect an additional 15 to 21 infected units per 107 donations, compared to licensed HBsAg tests. Sensitivity, WP closure, and yield projections for newer HBsAg assays and pooled-sample NAT are comparable. Single-sample NAT would increase yield by 13 to 15 units per 107 donations over pooled-sample NAT and newer HBsAg assays and by 35 to 50 units per 107 donations over currently licensed HBsAg assays.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app