We have located links that may give you full text access.
Accuracy of ultrasound dating formulae in the late second-trimester in pregnancies conceived with in-vitro fertilization.
Acta Radiologica 2003 July
PURPOSE: To investigate the accuracy of ultrasound dating formulae in the late second trimester of pregnancy.
MATERIAL AND METHODS: A dataset of 136 singleton pregnancies conceived by artificial reproductive techniques was studied to assess the accuracy of ultrasound dating formulae in the late second trimester, and compared with early second trimester. A total of 21 published ultrasound-dating formulae were tested.
RESULTS: For most formulae, late second trimester scans yielded results that were marginally less accurate than the early second trimester. The best performance was obtained with dating formulae based on femur length, either alone or combined with the biparietal diameter. These formulae had mean absolute errors of 3-3.5 days. Combining two or more parameters did not result in any substantial gain in accuracy.
CONCLUSIONS: Pregnancy dating by ultrasound in the late second trimester is sufficiently accurate for routine clinical use. Formulae based on femur length appear to be at least as accurate as head measurements.
MATERIAL AND METHODS: A dataset of 136 singleton pregnancies conceived by artificial reproductive techniques was studied to assess the accuracy of ultrasound dating formulae in the late second trimester, and compared with early second trimester. A total of 21 published ultrasound-dating formulae were tested.
RESULTS: For most formulae, late second trimester scans yielded results that were marginally less accurate than the early second trimester. The best performance was obtained with dating formulae based on femur length, either alone or combined with the biparietal diameter. These formulae had mean absolute errors of 3-3.5 days. Combining two or more parameters did not result in any substantial gain in accuracy.
CONCLUSIONS: Pregnancy dating by ultrasound in the late second trimester is sufficiently accurate for routine clinical use. Formulae based on femur length appear to be at least as accurate as head measurements.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app