We have located links that may give you full text access.
Comparative Study
Journal Article
Evaluation of the ulnopalmar arterial arches with pulse oximetry and plethysmography: comparison with the Allen's test in 1010 patients.
American Heart Journal 2004 March
BACKGROUND: To avoid ischemic hand complications, the percutaneous transradial approach is only performed in patients with patent hand collateral arteries, which is usually evaluated with the modified Allen's test (MAT). This qualitative test measures the time needed for maximal palmar blush after release of the ulnar artery compression with occlusive pressure of the radial artery. The objectives were to evaluate the patency of the hand collateral arteries and to compare MAT with combined plethysmography (PL) and pulse oximetry (OX) tests before the percutaneous transradial approach.
METHODS: Patients referred to the catheterization laboratory were prospectively examined with MAT, PL, and OX tests. PL readings during radial artery compression were divided into 4 types: A, no damping; B, slight damping of pulse tracing; C, loss followed by recovery; or D, no recovery of pulse tracing within 2 minutes. OX results were either positive or negative. Results of both tests were compared in 1010 consecutive patients.
RESULTS: MAT results < or =9 seconds on either hand were seen in 93.7% of patients. PL and OX types A, B, or C on either hand were seen in 98.5% of patients. On the basis of the MAT < or =9 seconds criteria, 6.3% of patients were excluded from the transradial approach, whereas with PL and OX types A, B, and C, only 1.5% of patients were excluded. There was more exclusion in men and with increasing age by using both methods.
CONCLUSIONS: In the evaluation of hand collaterals, PL and OX were found to be more sensitive than MAT. When applied to transradial approach screening, only 1.5% of patients were not suitable candidates for the transradial approach.
METHODS: Patients referred to the catheterization laboratory were prospectively examined with MAT, PL, and OX tests. PL readings during radial artery compression were divided into 4 types: A, no damping; B, slight damping of pulse tracing; C, loss followed by recovery; or D, no recovery of pulse tracing within 2 minutes. OX results were either positive or negative. Results of both tests were compared in 1010 consecutive patients.
RESULTS: MAT results < or =9 seconds on either hand were seen in 93.7% of patients. PL and OX types A, B, or C on either hand were seen in 98.5% of patients. On the basis of the MAT < or =9 seconds criteria, 6.3% of patients were excluded from the transradial approach, whereas with PL and OX types A, B, and C, only 1.5% of patients were excluded. There was more exclusion in men and with increasing age by using both methods.
CONCLUSIONS: In the evaluation of hand collaterals, PL and OX were found to be more sensitive than MAT. When applied to transradial approach screening, only 1.5% of patients were not suitable candidates for the transradial approach.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app