A meta-analysis of percutaneous vascular closure devices after diagnostic catheterization and percutaneous coronary intervention.
Journal of Invasive Cardiology 2004 May
BACKGROUND: While each of the available femoral arterial sealing devices claims equivalent safety to manual compression following invasive cardiac procedures, these claims are based on small, underpowered studies. Our aim was to increase the ability to detect a clinically meaningful difference by performing a meta-analysis.
METHODS: We identified studies via Medline and manual searches and selected studies that were prospective, randomized clinical trials for inclusion. Pooling of data was performed by calculation of the Mantel-Haenszel odds ratio (OR) and the variance of the OR was estimated using the method of Robins, Greenland and Breslow.
RESULTS: Sixteen studies enrolling 5,048 patients were included in the analysis. The pooled OR was 0.89 (95% confidence interval, 0.86-0.91), indicating a significant decrease in risk by devices. Excluding hematomas from the endpoint resulted in a concordant result. Angio-Seal was associated with a significant reduction in risk (OR, 0.51) and Perclose had a neutral result (OR, 1.0), whereas Vasoseal had an increased risk of complications (OR, 1.18).
CONCLUSION: Overall, sealing devices may be associated with a reduction in risk of complications following invasive coronary procedures, but significant differences may exist among individual devices. These potential differences need to be explored in randomized, controlled clinical trials.
METHODS: We identified studies via Medline and manual searches and selected studies that were prospective, randomized clinical trials for inclusion. Pooling of data was performed by calculation of the Mantel-Haenszel odds ratio (OR) and the variance of the OR was estimated using the method of Robins, Greenland and Breslow.
RESULTS: Sixteen studies enrolling 5,048 patients were included in the analysis. The pooled OR was 0.89 (95% confidence interval, 0.86-0.91), indicating a significant decrease in risk by devices. Excluding hematomas from the endpoint resulted in a concordant result. Angio-Seal was associated with a significant reduction in risk (OR, 0.51) and Perclose had a neutral result (OR, 1.0), whereas Vasoseal had an increased risk of complications (OR, 1.18).
CONCLUSION: Overall, sealing devices may be associated with a reduction in risk of complications following invasive coronary procedures, but significant differences may exist among individual devices. These potential differences need to be explored in randomized, controlled clinical trials.
Full text links
Trending Papers
A Personalized Approach to the Management of Congestion in Acute Heart Failure.Heart International 2023
Potential Mechanisms of the Protective Effects of the Cardiometabolic Drugs Type-2 Sodium-Glucose Transporter Inhibitors and Glucagon-like Peptide-1 Receptor Agonists in Heart Failure.International Journal of Molecular Sciences 2024 Februrary 21
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app