Diagnosing infection in the failed joint replacement: a comparison of coincidence detection 18F-FDG and 111In-labeled leukocyte/99mTc-sulfur colloid marrow imaging.

UNLABELLED: The objectives of this study were to investigate (18)F-FDG imaging, using a coincidence detection system, for diagnosing prosthetic joint infection and to compare it with combined (111)In-labeled leukocyte/(99m)Tc-sulfur colloid marrow imaging in patients with failed lower extremity joint replacements.

METHODS: Fifty-nine patients--with painful, failed, lower extremity joint prostheses, 40 hip and 19 knee--who underwent (18)F-FDG, labeled leukocyte, and bone marrow imaging, and had histopathologic and microbiologic confirmation of the final diagnosis, formed the basis of this investigation. (18)F-FDG images were interpreted as positive for infection using 4 different criteria: criterion 1: any periprosthetic activity, regardless of location or intensity; criterion 2: periprosthetic activity on the (18)F-FDG image, without corresponding activity on the marrow image; criterion 3: only bone-prosthesis interface activity, regardless of intensity; criterion 4: semiquantitative analysis--a lesion-to-background ratio was generated, and the cutoff value yielding the highest accuracy for determining the presence of infection was determined. Labeled leukocyte/marrow images were interpreted as positive for infection when periprosthetic activity was present on the labeled leukocyte image without corresponding activity on the marrow image.

RESULTS: Twenty-five (42%) prostheses, 14 hip and 11 knee, were infected. The sensitivity, specificity, and accuracy of (18)F-FDG, by criterion, were as follows: criterion 1: 100%, 9%, 47%; criterion 2: 96%, 35%, 61%; criterion 3: 52%, 44%, 47%; criterion 4: 36%, 97%, 71%. The sensitivity, specificity, and accuracy of labeled leukocyte/marrow imaging were 100%, 91%, and 95%, respectively. WBC/marrow imaging, which was more accurate than any of the (18)F-FDG criteria for all prostheses, as well as for hips and knees separately, was significantly more sensitive than criterion 3 (P < 0.001) and criterion 4 (P < 0.001) and was significantly more specific than criterion 1 (P < 0.001), criterion 2 (P < 0.001), and criterion 3 (P < 0.001).

CONCLUSION: Regardless of how the images are interpreted, coincidence detection-based (18)F-FDG imaging is less accurate than, and cannot replace, labeled leukocyte/marrow imaging for diagnosing infection of the failed prosthetic joint.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app