Conductive keratoplasty and the coupling phenomenon.
Eye & Contact Lens 2005 May
PURPOSE: To determine whether changes in corneal astigmatism with astigmatic conductive keratoplasty (CK) treatment obey Gaussian coupling (i.e., the steepening of the flat axis associated with the flattening of the steep axis) and to measure the coupling ratio and the coupling constant to determine the effect of astigmatic CK treatment on spherical equivalent.
METHODS: Retrospective review of 33 eyes in 24 patients who had undergone CK for hyperopia and who were treated intraoperatively for induced astigmatism. Induced astigmatism was determined by comparison of keratometric readings before and after CK.
RESULTS: The coupling ratio was calculated according to two equations: clinical coupling ratio (1.61 +/- 0.81 diopters) and coupling ratio of the surgically induced refractive change (1.57 +/- 1.16 diopters). Values of the coupling ratio between 0.72 and 1.88 indicate coupling.
CONCLUSIONS: The cornea does not behave according to Gauss's law of elastic domes. The targeted flat axis and steep axis 90 degrees away are affected by CK in opposite but not equal amounts. Therefore, when correcting surgically induced astigmatism with CK, the overall spherical equivalent of the patient will change because the coupling ratio is not equal to 1.
METHODS: Retrospective review of 33 eyes in 24 patients who had undergone CK for hyperopia and who were treated intraoperatively for induced astigmatism. Induced astigmatism was determined by comparison of keratometric readings before and after CK.
RESULTS: The coupling ratio was calculated according to two equations: clinical coupling ratio (1.61 +/- 0.81 diopters) and coupling ratio of the surgically induced refractive change (1.57 +/- 1.16 diopters). Values of the coupling ratio between 0.72 and 1.88 indicate coupling.
CONCLUSIONS: The cornea does not behave according to Gauss's law of elastic domes. The targeted flat axis and steep axis 90 degrees away are affected by CK in opposite but not equal amounts. Therefore, when correcting surgically induced astigmatism with CK, the overall spherical equivalent of the patient will change because the coupling ratio is not equal to 1.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app