Excimer laser photorefractive keratectomy for hyperopia: 7.5-year follow-up.

PURPOSE: To report the results of a long-term prospective study to evaluate refractive stability and safety of hyperopic photorefractive keratectomy (H-PRK).

SETTING: Department of Ophthalmology, St. Thomas' Hospital, London, United Kingdom.

METHODS: Twenty-one patients (49%) (40 eyes) of cohort of 43 patients who participated in 1 of the first clinical trials of H-PRK were assessed at a mean follow-up of 90.7 months (range 62 to 106 months). The H-PRK was performed using a Summit Technology Apex Plus Excimer laser (Summit Technology, Inc.). The mean preoperative spherical equivalent refraction (SEQ) was +4.70 diopters (D) (range +2.00 to +7.50 D). Patients were allocated to 1 of 4 treatment groups based on their preoperative refraction and received 1 of the following spherical corrections: +1.50 D, +3.00 D, +4.50 D, or +6.00 D.

RESULTS: At 7.5 years, the refractive correction remained stable with a mean difference in SEQ between 1 year and 7.5 years of +0.28 D. The mean manifest SEQ was +0.83 D (range +5.00 to -3.00 D). Sixty-seven percent of eyes having corrections of +1.50 D and +3.00 D were within +/-1.00 D of the predicted correction. Predictability was poorer with +4.50 D and +6.00 D corrections, with 40% of eyes within +/-1.00 D of that expected. An improvement in uncorrected near acuity was achieved in 35 eyes (87.5%), and 35 eyes (87.5%) showed an improvement in uncorrected distance acuity from preoperative levels. Best spectacle-corrected visual acuity (BSCVA) was unchanged or improved from preoperative values in 25 eyes (62.5%). Three eyes (8%) lost 2 lines of Snellen BSCVA, which in 2 cases was attributable to cataract formation. A peripheral ring of haze, 6.5 mm in diameter, appeared in most eyes. Its intensity was greatest at 6 months and then diminished with time. In 10 eyes (25%), remnants of the haze ring were evident at 7.5 years and subepithelial iron rings, 6.5 mm in diameter were evident in 26 eyes (70%). No patient complained of night-vision problems and no eye developed ectasia.

CONCLUSIONS: In H-PRK, refractive stability achieved at 1 year was maintained up to 7.5 years with no evidence of hyperopic shift, diurnal fluctuation, or late regression. Peripheral corneal haze decreased with time but was still evident in a number of eyes at the last follow-up visit.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app