We have located links that may give you full text access.
Clinical Trial
Comparative Study
Journal Article
Multicenter Study
Research Support, Non-U.S. Gov't
Compliance, quality of life and quantitative voice quality aspects of hands-free speech.
Acta Oto-laryngologica 2005 June
CONCLUSIONS: With the use of a new automatic stoma valve (ASV) it appears possible to rehabilitate patients who have previously been unsuccessful in acquiring hands-free speech. As well as making daily ASV use possible for an additional group of patients, this new device was also appreciated by many patients as an additional rehabilitation tool for specific occasions. Despite statistically significant improvements in aspects of voice and breathing using this novel ASV, improvement of peristomal adhesion is probably the main factor needed to further increase success rates. Nevertheless, our results show that it makes sense to keep trying to achieve hands-free speech, even if previous attempts have failed.
OBJECTIVE: To make a long-term (6 months) assessment of compliance and aspects of voice, breathing and quality of life using a new ASV: the Provox FreeHands heat and moisture exchanger (HME).
MATERIAL AND METHODS: This was a prospective clinical multicentre trial in 79 laryngectomized patients (8 regular ASV users, 58 previously unsuccessful users and 13 new users). Data were collected at baseline and after 1 and 6 months by means of European Organization for Research and Treatment of Cancer Quality of Life questionnaires and specific structured questionnaires concerning compliance, skin adhesion, voicing and pulmonary aspects. An objective assessment of voice parameters (maximum phonation time, maximum phonation time while counting, dynamic loudness range and number of pauses in a standard read-aloud text) was made for comparison of different stoma occlusion methods (digital occlusion via an HME and two different ASVs). A subjective assessment of overall voice quality was made.
RESULTS: After 6 months, 19% of patients used the new ASV on a daily basis (mean 5 h/day), while 57% used it on an irregular basis as an additional rehabilitation tool for special occasions. Two-thirds of the study group indicated that they would continue to use the new ASV after the study period. With respect to the objective parameters, statistically significantly better maximum phonation times and dynamic loudness ranges were observed with the new ASV compared to the Blom-Singer ASV. However, the best results for all the objective parameters were obtained with digital occlusion via the Provox HME.
OBJECTIVE: To make a long-term (6 months) assessment of compliance and aspects of voice, breathing and quality of life using a new ASV: the Provox FreeHands heat and moisture exchanger (HME).
MATERIAL AND METHODS: This was a prospective clinical multicentre trial in 79 laryngectomized patients (8 regular ASV users, 58 previously unsuccessful users and 13 new users). Data were collected at baseline and after 1 and 6 months by means of European Organization for Research and Treatment of Cancer Quality of Life questionnaires and specific structured questionnaires concerning compliance, skin adhesion, voicing and pulmonary aspects. An objective assessment of voice parameters (maximum phonation time, maximum phonation time while counting, dynamic loudness range and number of pauses in a standard read-aloud text) was made for comparison of different stoma occlusion methods (digital occlusion via an HME and two different ASVs). A subjective assessment of overall voice quality was made.
RESULTS: After 6 months, 19% of patients used the new ASV on a daily basis (mean 5 h/day), while 57% used it on an irregular basis as an additional rehabilitation tool for special occasions. Two-thirds of the study group indicated that they would continue to use the new ASV after the study period. With respect to the objective parameters, statistically significantly better maximum phonation times and dynamic loudness ranges were observed with the new ASV compared to the Blom-Singer ASV. However, the best results for all the objective parameters were obtained with digital occlusion via the Provox HME.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Diagnosis and Management of Cardiac Sarcoidosis: A Scientific Statement From the American Heart Association.Circulation 2024 April 19
Essential thrombocythaemia: A contemporary approach with new drugs on the horizon.British Journal of Haematology 2024 April 9
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app