Add like
Add dislike
Add to saved papers

Liquid bandage (2-octyl cyanoacrylate) as a temporary wound barrier in clear corneal cataract surgery.

Ophthalmology 2005 November
PURPOSE: To determine the feasibility and side effect profile of 2-octyl cyanoacrylate with parabens (Liquid Bandage) as an adjunct wound sealant and barrier against the inflow of ocular surface fluid after clear corneal cataract surgery.

DESIGN: Prospective interventional case series.

PARTICIPANTS: Fifty-one eyes of 51 patients undergoing clear corneal cataract surgery.

METHODS: Fifty-one eyes of 51 patients who underwent cataract surgery by one surgeon (RSK) were enrolled. A 2.75-mm clear corneal, triplanar, temporal incision was used in each case, followed by routine phacoemulsification. At the conclusion of each case, the wound was dried with a cellulose sponge. A modified microsponge with 1 to 2 drops of 2-octyl cyanoacrylate with parabens was then applied in a smooth layer to the wound. All wounds were rechecked for leakage with a cellulose sponge applied at the wound lip. The following criteria were evaluated on the first 2 postoperative visits: (1) visual acuity; (2) patient complaints; (3) wound integrity; (4) presence of tissue adhesive; and (5) any adverse events, including abnormal increase in local tissue reaction to the adhesive.

MAIN OUTCOME MEASURES: Side effect profile and clinical course of 2-octyl cyanoacrylate with parabens applied to clear corneal wounds.

RESULTS: All 51 eyes demonstrated intraoperative watertight wound closure after the application of 2-octyl cyanoacrylate with parabens. Forty-five eyes (88%) had tissue adhesive still completely covering the wound on postoperative day 1. Two eyes (4%) had tissue adhesive over portions of their wound, and 4 eyes (8%) had no adhesive noted on their wound. All wounds were watertight on all postoperative visits. Thirty-one of 51 patients (61%) complained of mild transient foreign body sensation on postoperative day 1. Twenty-six patients (51%) had trace diffuse bulbar conjunctival hyperemia. Five patients had trace focal conjunctival hyperemia adjacent to the wound. Nine patients (18%) had remnants of the adhesive remaining on the second postoperative visit.

CONCLUSIONS: Our study demonstrates the ease of use and applicability and low side effect profile of 2-octyl cyanoacrylate with parabens as a temporary wound barrier in clear corneal cataract surgery.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app