COMPARATIVE STUDY
JOURNAL ARTICLE
Add like
Add dislike
Add to saved papers

Comparison of failed and successful dacryocystorhinostomy by using computed tomographic dacryocystography findings.

PURPOSE: To compare the spiral computed tomographic dacryocystography (CT-DCG) findings of failed and successful dacryocystorhinostomies (DCR) and to detect the possible causes of failure before reoperation.

METHODS: Eighteen patients with failed and 15 patients with functional DCR were examined by spiral CT-DCG, a combination of contrast dacryocystography and spiral computed tomography. Radiologists, who were blinded to the clinical status of the patients, measured the diameter of the osteotomy window, evaluated its position relative to the lacrimal sac, and documented any abnormal findings around the osteotomy, which may contribute to the failure of DCR.

RESULTS: Location of the osteotomy window was inappropriate in 83% (15/18) of unsuccessful cases and in 7% (1/15) of successful cases and the difference was statistically significant (p < 0.01). Presence of the ethmoid air cells medial to the ostium was detected to have a significantly higher frequency in the unsuccessful DCR group (78%, 14/18) than in the successful group (20%, 3/15) (p < 0.01). The antero-posterior diameter of bony ostium was less than 15 mm in 94% (17/18) of failed DCR cases, but in only 60% (9/15) of successful DCR cases, and the difference was statistically significant (p < 0.05). Some additional findings that may contribute to the failure were noted in failed cases. There were ethmoid sinusitis in three, concha bullosa in two, nasal polyposis in two, mass in medial canthus in one, and extensive granulation tissue around the rhinostomy in one of the failed cases.

CONCLUSIONS: CT-DCG is a valuable imaging tool to evaluate DCR failures before reoperation. In this series, CT-DCG showed that small size and inappropriate position of osteotomy, and also extension of ethmoid air cells medial to the lacrimal sac, were frequently seen causative factors of DCR failure.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app