The safety of fluoroscopically-assisted thoracic pedicle screw instrumentation for spine trauma.
Journal of Trauma 2006 May
BACKGROUND: Pedicle screw fixation is considered biomechanically superior to other stabilization constructs. However, the potential for severe complications have discouraged its use in the thoracic spine. Our goal is to determine the incidence of major perioperative complications following the placement of thoracic pedicle screws using anatomic landmarks and intraoperative fluoroscopy in patients with spine fractures.
METHODS: Retrospective review of 245 consecutive patients with spine fractures requiring pedicle screw fixation between T1 and T10 at a regional Level I trauma center between 1995 and 2001. Database and medical record review were used to identify the incidence of major perioperative complications. A major complication was defined as a potentially life-threatening vascular injury, neurologic deterioration, pneumothorax or hemothorax, and tracheoesophageal injury. Patients were monitored for these complications from the time of surgery until discharge.
RESULTS: In all, 1,533 pedicle screws were placed between T1 and T10 in 245 patients. No patient sustained a major complication related to screw placement. Three patients (1.2%) required a secondary procedure for prophylactic revision of four (0.26%) malpositioned screws.
CONCLUSIONS: This study supports the safety of pedicle screws in the thoracic spine using preoperative imaging evaluation, standard posterior element landmarks and intraoperative fluoroscopy.
METHODS: Retrospective review of 245 consecutive patients with spine fractures requiring pedicle screw fixation between T1 and T10 at a regional Level I trauma center between 1995 and 2001. Database and medical record review were used to identify the incidence of major perioperative complications. A major complication was defined as a potentially life-threatening vascular injury, neurologic deterioration, pneumothorax or hemothorax, and tracheoesophageal injury. Patients were monitored for these complications from the time of surgery until discharge.
RESULTS: In all, 1,533 pedicle screws were placed between T1 and T10 in 245 patients. No patient sustained a major complication related to screw placement. Three patients (1.2%) required a secondary procedure for prophylactic revision of four (0.26%) malpositioned screws.
CONCLUSIONS: This study supports the safety of pedicle screws in the thoracic spine using preoperative imaging evaluation, standard posterior element landmarks and intraoperative fluoroscopy.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app