OBJECTIVES: The aim of our study was to evaluate the feasibility, the safety, and hemodynamic improvements induced by permanent para-Hisian pacing in patients with chronic atrial fibrillation and narrow QRS who underwent atrioventricular (AV) node ablation.
BACKGROUND: Right ventricular apical pacing, inducing asynchronous ventricular contraction, may impair cardiac function; permanent para-Hisian pacing could preserve interventricular synchrony and improve left ventricular function.
METHODS: After AV node ablation, 16 patients were implanted with a dual-chamber pacemaker connected to a screw-in lead positioned in close proximity to the His bundle and to a right ventricular apical lead. Clinical and echocardiographic data were collected at baseline and after two randomized six-month periods (with para-Hisian and conventional pacing).
RESULTS: During para-Hisian pacing, the interventricular electromechanical delay improved as well (34 +/- 18 ms) as during right apical pacing (47 +/- 19 ms), p < 0.05. Para-Hisian pacing allowed an improvement in New York Heart Association functional class (1.75 +/- 0.4 vs. 2.33 +/- 0.6 at baseline and 2.5 +/- 0.4 during apical pacing, p < 0.05 for both), in quality-of-life score (16.2 +/- 8.7 vs. 32.5 +/- 15.0 at baseline, p < 0.05), and in the 6-min walk test (431 +/- 73 m vs. 378 +/- 60 m at baseline and 360 +/- 71 m during apical pacing, p < 0.5 for both). Mitral and tricuspid regurgitation improved during para-Hisian pacing (1.22 +/- 0.8 and 1.46 +/- 0.5 index, respectively, vs. 1.68 +/- 0.6 [p < 0.05] and 1.62 +/- 0.7 [p = NS] index at baseline, respectively), with a slight worsening during apical pacing (1.93 +/- 1 and 1.93 +/- 0.7 index, respectively, p < 0.05 for both).
CONCLUSIONS: Permanent para-Hisian pacing is feasible and safe. Compared with conventional right apical pacing, it allows an improvement in functional and hemodynamic parameters over long-term follow-up.
BACKGROUND: Right ventricular apical pacing, inducing asynchronous ventricular contraction, may impair cardiac function; permanent para-Hisian pacing could preserve interventricular synchrony and improve left ventricular function.
METHODS: After AV node ablation, 16 patients were implanted with a dual-chamber pacemaker connected to a screw-in lead positioned in close proximity to the His bundle and to a right ventricular apical lead. Clinical and echocardiographic data were collected at baseline and after two randomized six-month periods (with para-Hisian and conventional pacing).
RESULTS: During para-Hisian pacing, the interventricular electromechanical delay improved as well (34 +/- 18 ms) as during right apical pacing (47 +/- 19 ms), p < 0.05. Para-Hisian pacing allowed an improvement in New York Heart Association functional class (1.75 +/- 0.4 vs. 2.33 +/- 0.6 at baseline and 2.5 +/- 0.4 during apical pacing, p < 0.05 for both), in quality-of-life score (16.2 +/- 8.7 vs. 32.5 +/- 15.0 at baseline, p < 0.05), and in the 6-min walk test (431 +/- 73 m vs. 378 +/- 60 m at baseline and 360 +/- 71 m during apical pacing, p < 0.5 for both). Mitral and tricuspid regurgitation improved during para-Hisian pacing (1.22 +/- 0.8 and 1.46 +/- 0.5 index, respectively, vs. 1.68 +/- 0.6 [p < 0.05] and 1.62 +/- 0.7 [p = NS] index at baseline, respectively), with a slight worsening during apical pacing (1.93 +/- 1 and 1.93 +/- 0.7 index, respectively, p < 0.05 for both).
CONCLUSIONS: Permanent para-Hisian pacing is feasible and safe. Compared with conventional right apical pacing, it allows an improvement in functional and hemodynamic parameters over long-term follow-up.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app