Prosthesis infection: diagnosis after total joint arthroplasty with antigranulocyte scintigraphy with 99mTc-labeled monoclonal antibodies--a meta-analysis.
Radiology 2007 January
PURPOSE: To perform a meta-analysis of diagnostic studies regarding the accuracy of antigranulocyte scintigraphy (AGS) with monoclonal antibodies in the identification of prosthesis infection after total hip or knee arthroplasty.
MATERIALS AND METHODS: PubMed and EMBASE searches were conducted for the identification of relevant studies. Data on the diagnostic performance of AGS with monoclonal antibodies were combined quantitatively across eligible studies, and the overall sensitivity and specificity, along with summary receiver operating characteristic (ROC) curves and likelihood ratios (LRs), were estimated. The above parameters were evaluated for all patients and for various subgroups among the eligible studies. The reference standard used in the individual studies was accepted.
RESULTS: Thirteen eligible studies on nonoverlapping patient groups were included in the meta-analysis; there was a total sample size of 522 implants. The independent random effects summary estimates of sensitivity and specificity were 83% and 80%, respectively. The summary ROC curve estimate for weighted analysis was a sensitivity of 90% for a specificity of 80%. LR syntheses gave a weighted positive LR of 3.99 (95% confidence interval [CI]: 3.13, 5.09) and a weighted negative LR of 0.22 (95% CI: 0.15, 0.34); there was no statistically significant between-study heterogeneity for either metric. Various subgroup analyses did not reveal any statistically significant differences.
CONCLUSION: AGS with monoclonal antibodies had a reasonably high discriminating ability to identify prosthesis infection in patients who underwent total joint arthroplasty.
MATERIALS AND METHODS: PubMed and EMBASE searches were conducted for the identification of relevant studies. Data on the diagnostic performance of AGS with monoclonal antibodies were combined quantitatively across eligible studies, and the overall sensitivity and specificity, along with summary receiver operating characteristic (ROC) curves and likelihood ratios (LRs), were estimated. The above parameters were evaluated for all patients and for various subgroups among the eligible studies. The reference standard used in the individual studies was accepted.
RESULTS: Thirteen eligible studies on nonoverlapping patient groups were included in the meta-analysis; there was a total sample size of 522 implants. The independent random effects summary estimates of sensitivity and specificity were 83% and 80%, respectively. The summary ROC curve estimate for weighted analysis was a sensitivity of 90% for a specificity of 80%. LR syntheses gave a weighted positive LR of 3.99 (95% confidence interval [CI]: 3.13, 5.09) and a weighted negative LR of 0.22 (95% CI: 0.15, 0.34); there was no statistically significant between-study heterogeneity for either metric. Various subgroup analyses did not reveal any statistically significant differences.
CONCLUSION: AGS with monoclonal antibodies had a reasonably high discriminating ability to identify prosthesis infection in patients who underwent total joint arthroplasty.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app