We have located links that may give you full text access.
COMPARATIVE STUDY
JOURNAL ARTICLE
META-ANALYSIS
Stent thrombosis in randomized clinical trials of drug-eluting stents.
New England Journal of Medicine 2007 March 9
BACKGROUND: Definitions of stent thrombosis that have been used in clinical trials of drug-eluting stents have been restrictive and have not been used in a uniform manner.
METHODS: We applied a hierarchical classification of stent thrombosis set by the Academic Research Consortium (ARC) across randomized trials involving 878 patients treated with sirolimus-eluting stents, 1400 treated with paclitaxel-eluting stents, and 2267 treated with bare-metal stents. We then pooled 4 years of follow-up data. All events were adjudicated by an independent clinical-events committee.
RESULTS: The cumulative incidence of stent thrombosis according to the original protocol definitions was 1.2% in the sirolimus-stent group versus 0.6% in the bare-metal-stent group (P=0.20; 95% confidence interval [CI], -0.4 to 1.5) and 1.3% in the paclitaxel-stent group versus 0.8% in the bare-metal-stent group (P=0.24; 95% CI, -0.3 to 1.4). The incidence of definite or probable stent thrombosis as defined by the ARC was 1.5% in the sirolimus-stent group versus 1.7% in the bare-metal-stent group (P=0.70; 95% CI, -1.5 to 1.0) and 1.8% in the paclitaxel-stent group versus 1.4% in the bare-metal-stent group (P=0.52; 95% CI, -0.7 to 1.4). The incidence of definite or probable events occurring 1 to 4 years after implantation was 0.9% in the sirolimus-stent group versus 0.4% in the bare-metal-stent group and 0.9% in the paclitaxel-stent group versus 0.6% in the bare-metal-stent group.
CONCLUSIONS: The incidence of stent thrombosis did not differ significantly between patients with drug-eluting stents and those with bare-metal stents in randomized clinical trials, although the power to detect small differences in rates was limited.
METHODS: We applied a hierarchical classification of stent thrombosis set by the Academic Research Consortium (ARC) across randomized trials involving 878 patients treated with sirolimus-eluting stents, 1400 treated with paclitaxel-eluting stents, and 2267 treated with bare-metal stents. We then pooled 4 years of follow-up data. All events were adjudicated by an independent clinical-events committee.
RESULTS: The cumulative incidence of stent thrombosis according to the original protocol definitions was 1.2% in the sirolimus-stent group versus 0.6% in the bare-metal-stent group (P=0.20; 95% confidence interval [CI], -0.4 to 1.5) and 1.3% in the paclitaxel-stent group versus 0.8% in the bare-metal-stent group (P=0.24; 95% CI, -0.3 to 1.4). The incidence of definite or probable stent thrombosis as defined by the ARC was 1.5% in the sirolimus-stent group versus 1.7% in the bare-metal-stent group (P=0.70; 95% CI, -1.5 to 1.0) and 1.8% in the paclitaxel-stent group versus 1.4% in the bare-metal-stent group (P=0.52; 95% CI, -0.7 to 1.4). The incidence of definite or probable events occurring 1 to 4 years after implantation was 0.9% in the sirolimus-stent group versus 0.4% in the bare-metal-stent group and 0.9% in the paclitaxel-stent group versus 0.6% in the bare-metal-stent group.
CONCLUSIONS: The incidence of stent thrombosis did not differ significantly between patients with drug-eluting stents and those with bare-metal stents in randomized clinical trials, although the power to detect small differences in rates was limited.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app