In vitro comparison of conventional film and direct digital imaging in the detection of approximal caries.
Dento Maxillo Facial Radiology 2007 March
OBJECTIVES: To compare the diagnostic accuracy of conventional film, unenhanced direct digital and inversion grayscale direct digital imaging in the detection of approximal caries.
METHODS: 150 approximal surfaces of extracted permanent molars and premolars were selected for the study on the basis of varying lesion depth. The teeth were radiographed using Ektaspeed Plus film; digital images were made with a Schick CMOS-APS sensor. 7 examiners evaluated 58 randomized images of each modality. Histological sectioning of the teeth was used to verify the presence and extent of decay.
RESULTS: No significant difference was found between the diagnostic accuracies of the three imaging modalities (P=0.226). Analysis of the diagnostic accuracy of the three modalities on lesion depth showed no statistically significant interaction; however, the main effect of the lesion depth was significant (P<0.001, eta(2)=0.936).
CONCLUSIONS: The overall diagnostic accuracy of the three modalities in the detection of approximal carious lesions was comparable. All three modalities performed poorly in the detection of enamel lesions.
METHODS: 150 approximal surfaces of extracted permanent molars and premolars were selected for the study on the basis of varying lesion depth. The teeth were radiographed using Ektaspeed Plus film; digital images were made with a Schick CMOS-APS sensor. 7 examiners evaluated 58 randomized images of each modality. Histological sectioning of the teeth was used to verify the presence and extent of decay.
RESULTS: No significant difference was found between the diagnostic accuracies of the three imaging modalities (P=0.226). Analysis of the diagnostic accuracy of the three modalities on lesion depth showed no statistically significant interaction; however, the main effect of the lesion depth was significant (P<0.001, eta(2)=0.936).
CONCLUSIONS: The overall diagnostic accuracy of the three modalities in the detection of approximal carious lesions was comparable. All three modalities performed poorly in the detection of enamel lesions.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app