We have located links that may give you full text access.
CLINICAL TRIAL
JOURNAL ARTICLE
MULTICENTER STUDY
RESEARCH SUPPORT, NON-U.S. GOV'T
Safety and outcomes of balloon catheter sinusotomy: a multicenter 24-week analysis in 115 patients.
Otolaryngology - Head and Neck Surgery 2007 July
OBJECTIVE: The aim of this study was to further evaluate the safety and effectiveness of balloon catheter devices to dilate obstructed sinus ostia/perform sinusotomy.
METHODS: Through a prospective, multicenter evaluation, safety was assessed by rate of adverse events, patency was determined by endoscopic examination, and sinus symptoms were determined by the Sino-Nasal Outcome Test (SNOT 20).
RESULTS: At the conclusion of the 24-week analysis, endoscopy determined that the sinusotomy was patent in 80.5% (247 of 307) sinuses and nonpatent in 1.6% (5 of 307), and could not determine ostial patency status in 17.9% (55 of 307). Of the ostia visualized on endoscopy, 98% were patent (247 of 252), while 2% (5 of 252) were considered nonpatent. SNOT 20 scores showed consistent symptomatic improvement over baseline. Revision treatment was required in 3 sinuses (3 of 307 sinuses, 0.98%) in 3 patients (3 of 109 patients, 2.75%).
CONCLUSION: Balloon catheter technology appears safe and effective in relieving ostial obstruction. Patients were pleased and indicated that they experienced symptomatic improvement.
METHODS: Through a prospective, multicenter evaluation, safety was assessed by rate of adverse events, patency was determined by endoscopic examination, and sinus symptoms were determined by the Sino-Nasal Outcome Test (SNOT 20).
RESULTS: At the conclusion of the 24-week analysis, endoscopy determined that the sinusotomy was patent in 80.5% (247 of 307) sinuses and nonpatent in 1.6% (5 of 307), and could not determine ostial patency status in 17.9% (55 of 307). Of the ostia visualized on endoscopy, 98% were patent (247 of 252), while 2% (5 of 252) were considered nonpatent. SNOT 20 scores showed consistent symptomatic improvement over baseline. Revision treatment was required in 3 sinuses (3 of 307 sinuses, 0.98%) in 3 patients (3 of 109 patients, 2.75%).
CONCLUSION: Balloon catheter technology appears safe and effective in relieving ostial obstruction. Patients were pleased and indicated that they experienced symptomatic improvement.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app