The Amplatzer Membranous VSD Occluder and the vulnerability of the atrioventricular conduction system.

Transcatheter closure of ventricular septal defects with the Amplatzer Membranous VSD Occluder has yielded promising initial results, but disturbances of conduction, including complete heart block, have been reported. We report our experience with the Amplatzer occluder in 35 patients with a median age 4.5 years, the defects being sized angiographically at 4.4 plus or minus 1.1 millimetres, with a range from 3 to 8 millimetres, and the size of the occluder varying from 4 to 12 millimetres. Over a median follow-up of 2.5 years, the rate of complete closure was 87% and 91%, at 1 and 2 years respectively, while 2 patients required surgical closure of the defect subsequent to the insertion of the device. Persistent regurgitation across the tricuspid valve related to the occluder was observed in 3 patients, and in 6 patients across the aortic valve. Abnormalities of conduction related to the procedure were noted in 7 patients, one-fifth of the cohort. The disturbances were transient in 1 patient, but permanent in 6, in one of the latter progressing after 6 months from left bundle branch block to intermittent Mobitz II second-degree atrioventricular block in association with expansion of the occluder. We conclude that transcatheter closure of perimembranous ventricular septal defects with the Amplatzer occluder is effective with limited complications, but the incidence of immediate and progressive disturbances of conduction related to the proximity of conduction tissues to the rims of the occluder stress the importance of larger and longer studies to assess the safety of this procedure.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app