Evaluation Study
Journal Article
Multicenter Study
Add like
Add dislike
Add to saved papers

Computerized fetal heart rate analysis, Doppler ultrasound and biophysical profile score in the prediction of acid-base status of growth-restricted fetuses.

OBJECTIVE: To investigate the performance of non-stress test (NST), computerized fetal heart rate analysis (cCTG), biophysical profile scoring (BPS) and arterial and venous Doppler ultrasound investigation in the prediction of acid-base status in fetal growth restriction.

METHODS: Growth-restricted fetuses, defined by abdominal circumference < 5(th) percentile and umbilical artery (UA) pulsatility index > 95(th) percentile, were tested by NST, cCTG, BPS, and UA, middle cerebral artery (MCA), ductus venosus (DV) and umbilical vein (UV) Doppler investigation. The short-term variation (STV) of the fetal heart rate was calculated using the Oxford Sonicaid 8002 cCTG system. Relationships between antenatal test results and cord artery pH < 7.20 were investigated, using correlation, parametric and non-parametric tests.

RESULTS: Fifty-six of 58 patients (96.6%) received complete assessment of all variables. All were delivered by pre-labor Cesarean section at a median gestational age of 30 + 6 weeks. The UA pulsatility index (PI) was negatively correlated with the cCTG STV (Pearson correlation - 0.29, P < 0.05). The DV PI was negatively correlated with the pH (Pearson correlation - 0.30, P < 0.02). The cCTG mean minute variation and pH were not significantly correlated (Pearson correlation 0.13, P = 0.34). UV pulsations identified the highest proportion of neonates with a low birth pH (9/17, 53%), the highest number of false positives among patients with an abnormal BPS, abnormal DV Doppler and a STV < 3.5 ms, and also stratified false negatives among patients with an equivocal or normal BPS. Abnormal DV Doppler correctly identified false positives among patients with an abnormal BPS. cCTG reduced the rate of an equivocal BPS from 16% to 7.1% when substituted for the traditional NST. Elevated DV Doppler index and umbilical venous pulsations predicted a low pH with 73% sensitivity and 90% specificity (P = 0.008).

CONCLUSION: In fetal growth restriction with placental insufficiency, venous Doppler investigation provides the best prediction of acid-base status. The cCTG performs best when combined with venous Doppler or as a substitute for the traditional NST in the BPS.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app