Adjunctive use of C-arm CT may eliminate technical failure in adrenal vein sampling.
Journal of Vascular and Interventional Radiology : JVIR 2007 September
PURPOSE: To examine whether the use of C-arm computed tomography (CT) during adrenal vein sampling improves the technical success rate of the procedure.
MATERIALS AND METHODS: Nine consecutive patients with suspected primary hyperaldosteronism underwent standard adrenal vein sampling that included cortisol stimulation. The procedure was augmented with multiplanar C-arm CT images reconstructed from data acquired during a 180 degrees C-arm rotation. Whenever C-arm CT images showed the sampling catheter to be in the wrong position, the catheter was repositioned. Cortisol response was correlated to C-arm CT findings.
RESULTS: All patients had successful and diagnostic adrenal vein sampling. C-arm CT showed sampling catheter malposition in two patients (22%). Repeat C-arm CT after repositioning showed proper catheter location. Cortisol stimulation results and C-arm CT findings were concordant in 100% of cases.
CONCLUSIONS: C-arm CT is reliable in confirming the location of sampling catheters during adrenal vein sampling. If the 100% concordance between cortisol stimulation and C-arm CT findings is found in larger groups, the technical success rate may approach 100%. Cortisol stimulation may become obsolete and repeat procedures unnecessary, with significant time and cost savings.
MATERIALS AND METHODS: Nine consecutive patients with suspected primary hyperaldosteronism underwent standard adrenal vein sampling that included cortisol stimulation. The procedure was augmented with multiplanar C-arm CT images reconstructed from data acquired during a 180 degrees C-arm rotation. Whenever C-arm CT images showed the sampling catheter to be in the wrong position, the catheter was repositioned. Cortisol response was correlated to C-arm CT findings.
RESULTS: All patients had successful and diagnostic adrenal vein sampling. C-arm CT showed sampling catheter malposition in two patients (22%). Repeat C-arm CT after repositioning showed proper catheter location. Cortisol stimulation results and C-arm CT findings were concordant in 100% of cases.
CONCLUSIONS: C-arm CT is reliable in confirming the location of sampling catheters during adrenal vein sampling. If the 100% concordance between cortisol stimulation and C-arm CT findings is found in larger groups, the technical success rate may approach 100%. Cortisol stimulation may become obsolete and repeat procedures unnecessary, with significant time and cost savings.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app