EVALUATION STUDIES
JOURNAL ARTICLE
Add like
Add dislike
Add to saved papers

Performance of a computer-aided program for automated matching of metastatic pulmonary nodules detected on follow-up chest CT.

OBJECTIVE: The purpose of this study was to evaluate the performance of a computer-aided program that allows automated matching of metastatic pulmonary nodules imaged with two serial clinical chest CT studies.

MATERIALS AND METHODS: The cases of 30 patients with metastatic pulmonary nodules depicted on two serial clinical MDCT scans (16- or 64-MDCT, 5-mm section thickness) were studied. The number of nodules per patient varied from a minimum of two to innumerable. A maximum of 10 well-defined solid nodules per patient, a total of 210 nodules, were selected from each baseline CT scan and were evaluated for matching detection in follow-up CT by means of an automated program. Substantial changes in lung findings and lung volumes between serial scans were visually assessed. The effects on matching rate of interval lung changes and location, size, and total number of nodules in the lung were analyzed with contingency tables. Chi-square tests were used to evaluate patterns for statistical significance.

RESULTS: The nodule-matching rate per patient ranged from 0 to 100% (median, 87.5%). By nodule, the overall matching rate was 140 of 210 (66.7%). Matching rate was highly associated with changes in lung quality between serial studies. Matching of 122 of 148 nodules (82.4%) occurred in 23 patients with relatively unchanged lung findings, compared with 18 of 62 nodules (29.0%) in seven patients with substantial interval changes (p < 0.001). The matching rate decreased with an increased total number of nodules per lung. For 10 or fewer nodules per lung, matching was successful for 31 of 36 nodules; for 11-50 nodules per lung, 60 of 73 nodules; for 51-100 nodules per lung, 33 of 47 nodules; and for more than 100 nodules per lung, 16 of 54 nodules (p < 0.001). The matching rate was not significantly different with location or size of nodules.

CONCLUSION: The rate of automated matching of metastatic pulmonary nodules on clinical serial CT scans was high (82.4%) when the lung findings and lung expansion between the serial scans were relatively unchanged. The rate decreased significantly, however, with substantial interval changes in the lung and a larger number of nodules.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app