Surgical treatment of strabismus secondary to glaucoma drainage device.
Archives of Ophthalmology 2008 April
OBJECTIVE: To describe surgical strategies in a series of patients with diplopia following implantation of a glaucoma drainage device.
METHODS: Retrospective review of 9 consecutive patients who underwent strabismus surgery because of strabismus and diplopia after implantation of a glaucoma drainage device.
RESULTS: Seven patients with marked limitation to ocular rotations and incomitant strabismus underwent surgery on the eye with the implant. Two patients with mild limitation to ocular rotations of the involved eye underwent surgery on the contralateral eye. All patients had a large fibrous capsule surrounding the implant plate, adjacent muscles, and sclera. Intraocular pressure was not elevated postoperatively. Postoperative diplopia in the primary position was eliminated in 5 patients and markedly improved in 3 patients.
CONCLUSIONS: Strabismus following implantation of a glaucoma drainage device is an uncommon but serious complication. Restoration of ocular alignment is a complex undertaking requiring strabismus and glaucoma surgical expertise. Multiple surgical complications may occur. Surgical intervention may require complete removal of the fibrous capsule surrounding the implant and involved adjacent structures. Size reduction of the implant plate is helpful and did not interfere with postoperative intraocular pressure control in this study. Surgery on the contralateral eye is an option in patients with mild restriction.
METHODS: Retrospective review of 9 consecutive patients who underwent strabismus surgery because of strabismus and diplopia after implantation of a glaucoma drainage device.
RESULTS: Seven patients with marked limitation to ocular rotations and incomitant strabismus underwent surgery on the eye with the implant. Two patients with mild limitation to ocular rotations of the involved eye underwent surgery on the contralateral eye. All patients had a large fibrous capsule surrounding the implant plate, adjacent muscles, and sclera. Intraocular pressure was not elevated postoperatively. Postoperative diplopia in the primary position was eliminated in 5 patients and markedly improved in 3 patients.
CONCLUSIONS: Strabismus following implantation of a glaucoma drainage device is an uncommon but serious complication. Restoration of ocular alignment is a complex undertaking requiring strabismus and glaucoma surgical expertise. Multiple surgical complications may occur. Surgical intervention may require complete removal of the fibrous capsule surrounding the implant and involved adjacent structures. Size reduction of the implant plate is helpful and did not interfere with postoperative intraocular pressure control in this study. Surgery on the contralateral eye is an option in patients with mild restriction.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app