An evaluation of the osmole gap as a screening test for toxic alcohol poisoning.

BACKGROUND: The osmole gap is used routinely as a screening test for the presence of exogenous osmotically active substances, such as the toxic alcohols ethylene glycol and methanol, particularly when the ability to measure serum concentrations of the substances is not available. The objectives of this study were: 1) to measure the diagnostic accuracy of the osmole gap for screening for ethylene glycol and methanol exposure, and 2) to identify whether a recently proposed modification of the ethanol coefficient affects the diagnostic accuracy.

METHODS: Electronic laboratory records from two tertiary-care hospitals were searched to identify all patients for whom a serum ethylene glycol and methanol measurement was ordered between January 1, 1996 and March 31, 2002. Cases were eligible for analysis if serum sodium, blood urea nitrogen, glucose, ethanol, ethylene glycol, methanol, and osmolality were measured simultaneously. Serum molarity was calculated using the Smithline and Gardner equation and ethanol coefficients of 1 and 1.25 mOsm/mM. The diagnostic accuracy of the osmole gap was evaluated for identifying patients with toxic alcohol levels above the recommended threshold for antidotal therapy and hemodialysis using receiver-operator characteristic curves, likelihood ratios, and positive and negative predictive values.

RESULTS: One hundred and thirty-one patients were included in the analysis, 20 of whom had ethylene glycol or methanol serum concentrations above the threshold for antidotal therapy. The use of an ethanol coefficient of 1.25 mOsm/mM yielded higher specificities and positive predictive values, without affecting sensitivity and negative predictive values. Employing an osmole gap threshold of 10 for the identification of patients requiring antidotal therapy resulted in a sensitivity of 0.9 and 0.85, and a specificity of 0.22 and 0. 5, with equations 1 and 2 respectively. The sensitivity increased to 1 for both equations for the identification of patients requiring dialysis.

CONCLUSION: In this sample, an osmole gap threshold of 10 has a sensitivity and negative predictive value of 1 for identifying patients for whom hemodialysis is recommended, independent of the ethanol coefficient applied. In patients potentially requiring antidotal therapy, applying an ethanol coefficient of 1.25 resulted in a higher specificity and positive predictive value without compromising the sensitivity.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app