An unusual case of button battery-induced traumatic tracheoesophageal fistula.
Pediatric Emergency Care 2008 May
BACKGROUND: Much of pediatric medicine is focused on prevention of disease and injury. Although accidental ingestions of various household chemicals and medicines are well described and the treatment is supported by local poison control hotlines, the ingestion of button batteries by children is less publicized, and the dangers are less understood by both parents and health care providers.
METHODS: We describe a case report of a 17-month-old girl with no significant medical history who presented with respiratory distress, cough, and fever and subsequently was discovered to have ingested a button battery.
RESULTS: The formation of a traumatic tracheoesophageal fistula required intensive management that escalated to cardiopulmonary bypass and eventual pericardial patch closure of the tracheal defect after the failure of conventional mechanical ventilation.
CONCLUSIONS: Esophageal button battery impaction places the patient at high risk for full-thickness damage to the esophagus and tracheal structures with fistula formation in as little as a few hours. The key to successful therapy is prompt diagnosis and removal, but in nonverbal pediatric patients, this often is not achievable. Because of the complications associated with this disease (tracheoesophageal fistula) and subsequent difficulties associated with oxygenation and ventilation, these patients should be managed at an institution with the skilled capability of providing cardiopulmonary bypass quickly as a potentially lifesaving therapy.
METHODS: We describe a case report of a 17-month-old girl with no significant medical history who presented with respiratory distress, cough, and fever and subsequently was discovered to have ingested a button battery.
RESULTS: The formation of a traumatic tracheoesophageal fistula required intensive management that escalated to cardiopulmonary bypass and eventual pericardial patch closure of the tracheal defect after the failure of conventional mechanical ventilation.
CONCLUSIONS: Esophageal button battery impaction places the patient at high risk for full-thickness damage to the esophagus and tracheal structures with fistula formation in as little as a few hours. The key to successful therapy is prompt diagnosis and removal, but in nonverbal pediatric patients, this often is not achievable. Because of the complications associated with this disease (tracheoesophageal fistula) and subsequent difficulties associated with oxygenation and ventilation, these patients should be managed at an institution with the skilled capability of providing cardiopulmonary bypass quickly as a potentially lifesaving therapy.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app