We have located links that may give you full text access.
JOURNAL ARTICLE
RESEARCH SUPPORT, NON-U.S. GOV'T
Long-term relationship between intraocular pressure and visual field loss in primary open-angle glaucoma.
Journal of Glaucoma 2008 June
PURPOSE: To investigate the dependence upon intraocular pressure (IOP) of the progression of visual field defects in eyes with primary open-angle glaucoma (POAG), in which the mean IOP was maintained at < or =21 mm Hg.
METHODS: This study involved 100 eyes with POAG, which were followed up for > or =5 years. The mean IOP levels were maintained at < or =21 mm Hg during the follow-up period. The relationship between the IOP and the progression of visual field defects, which was scored using the Advanced Glaucoma Intervention Study criteria, was investigated retrospectively.
RESULTS: Compared with the baseline scores, the visual field defect scores had significantly worsened by the end of the follow-up period (P<0.0001, Wilcoxon paired signed rank test). The change in the visual field defect score (2.5+/-0.5) in eyes with average IOP levels of > or =16 mm Hg (n=36) was significantly greater (P=0.031, Mann-Whitney U test) than the change (1.3+/-0.3) in eyes with average IOP levels of <16 mm Hg (n=64). Moreover, IOP of > or =18 mm Hg made a major contribution to the aggravation of visual field defects in eyes with POAG.
CONCLUSIONS: Eyes with POAG and with mean IOP levels maintained at < or =21 mm Hg underwent IOP-dependent progression of their visual field defects. Our results suggest that further IOP lowering would be beneficial in such cases.
METHODS: This study involved 100 eyes with POAG, which were followed up for > or =5 years. The mean IOP levels were maintained at < or =21 mm Hg during the follow-up period. The relationship between the IOP and the progression of visual field defects, which was scored using the Advanced Glaucoma Intervention Study criteria, was investigated retrospectively.
RESULTS: Compared with the baseline scores, the visual field defect scores had significantly worsened by the end of the follow-up period (P<0.0001, Wilcoxon paired signed rank test). The change in the visual field defect score (2.5+/-0.5) in eyes with average IOP levels of > or =16 mm Hg (n=36) was significantly greater (P=0.031, Mann-Whitney U test) than the change (1.3+/-0.3) in eyes with average IOP levels of <16 mm Hg (n=64). Moreover, IOP of > or =18 mm Hg made a major contribution to the aggravation of visual field defects in eyes with POAG.
CONCLUSIONS: Eyes with POAG and with mean IOP levels maintained at < or =21 mm Hg underwent IOP-dependent progression of their visual field defects. Our results suggest that further IOP lowering would be beneficial in such cases.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app