The Groningen Longitudinal Glaucoma Study. II. A prospective comparison of frequency doubling perimetry, the GDx nerve fibre analyser and standard automated perimetry in glaucoma suspect patients.
Acta Ophthalmologica 2009 June
PURPOSE: We aimed to determine prospectively the incidence of abnormal test results on frequency doubling perimetry (FDT), the nerve fibre analyser (GDx) and standard automated perimetry (SAP) in a cohort of glaucoma suspect patients with normal findings for all these tests at baseline.
METHODS: Seventy glaucoma suspect patients were followed prospectively for 4 years with SAP (Humphrey field analyser 30-2 SITA Fast), FDT (C-20 full-threshold) and GDx (Version 2.010) in a clinical setting. All patients had normal baseline test results on SAP, FDT and GDx. After the follow-up period, the number of patients who converted (whose test results changed from normal at baseline to reproducibly abnormal during follow-up) were counted for each technique and then compared. The cut-off point for FDT was > 1 depressed test-point p < 0.01 in the total deviation probability plot; the cut-off point for GDx was the Number > 29.
RESULTS: Of the 70 glaucoma suspect patients, three converted on FDT, 14 on GDx and six on SAP. These proportions are significantly different for GDx versus SAP (p = 0.033) and GDx versus FDT (p = 0.002), but not for FDT versus SAP (p = 0.256).
CONCLUSIONS: The most frequent finding after a 4-year follow-up was conversion on GDx.
METHODS: Seventy glaucoma suspect patients were followed prospectively for 4 years with SAP (Humphrey field analyser 30-2 SITA Fast), FDT (C-20 full-threshold) and GDx (Version 2.010) in a clinical setting. All patients had normal baseline test results on SAP, FDT and GDx. After the follow-up period, the number of patients who converted (whose test results changed from normal at baseline to reproducibly abnormal during follow-up) were counted for each technique and then compared. The cut-off point for FDT was > 1 depressed test-point p < 0.01 in the total deviation probability plot; the cut-off point for GDx was the Number > 29.
RESULTS: Of the 70 glaucoma suspect patients, three converted on FDT, 14 on GDx and six on SAP. These proportions are significantly different for GDx versus SAP (p = 0.033) and GDx versus FDT (p = 0.002), but not for FDT versus SAP (p = 0.256).
CONCLUSIONS: The most frequent finding after a 4-year follow-up was conversion on GDx.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app