We have located links that may give you full text access.
Redilation of e-PTFE covered CP stents.
Catheterization and Cardiovascular Interventions 2008 August 2
OBJECTIVES: To evaluate the possibility to redilate covered Cheatham-Platinum stents during follow-up, in particular in growing children with aortic coarctation.
BACKGROUND: There are no data in the literature about the redilation of ePTFE covered CP stents.
METHODS: Sixty covered CP stents were implanted in patients with aortic coarctation or recoarctation between January 2004 and October 2007. Seven patients (mean age 14.2 +/- 3.7 years) needed to repeat the hemodynamic study due to somatic growth and increase of aortic gradient with the occurrence of systemic hypertension. Two had near-atretic aortic coarctation, three had postsurgical recoarctation and aneurysm formation, one had native aortic coarctation associated with aneurysm of the arterial wall, and one had severe native aortic coarctation.
RESULTS: Procedures were performed a mean of 20 +/- 5 months (range, 12-24 months) after the primary stent implantation. Fluoroscopy time ranged between 7 and 15 min (median, 10 min) whereas procedure time ranged between 60 and 75 min (median, 65 min). After redilation the gradient across the stenosis decreased from a median value of 35 mm Hg to a median value of 5 mm Hg. The stent diameter increased of 20-50% the predilation value. No complications occurred and angiographic controls showed that the stenoses have been relieved.
FOLLOW-UP: During a median follow-up of 12 months (6-30 months) the results were stable without complications.
CONCLUSION: Covered Cheatham-Platinum stents can be easily redilated.
BACKGROUND: There are no data in the literature about the redilation of ePTFE covered CP stents.
METHODS: Sixty covered CP stents were implanted in patients with aortic coarctation or recoarctation between January 2004 and October 2007. Seven patients (mean age 14.2 +/- 3.7 years) needed to repeat the hemodynamic study due to somatic growth and increase of aortic gradient with the occurrence of systemic hypertension. Two had near-atretic aortic coarctation, three had postsurgical recoarctation and aneurysm formation, one had native aortic coarctation associated with aneurysm of the arterial wall, and one had severe native aortic coarctation.
RESULTS: Procedures were performed a mean of 20 +/- 5 months (range, 12-24 months) after the primary stent implantation. Fluoroscopy time ranged between 7 and 15 min (median, 10 min) whereas procedure time ranged between 60 and 75 min (median, 65 min). After redilation the gradient across the stenosis decreased from a median value of 35 mm Hg to a median value of 5 mm Hg. The stent diameter increased of 20-50% the predilation value. No complications occurred and angiographic controls showed that the stenoses have been relieved.
FOLLOW-UP: During a median follow-up of 12 months (6-30 months) the results were stable without complications.
CONCLUSION: Covered Cheatham-Platinum stents can be easily redilated.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app