Plain films in the evaluation of batteries as esophageal foreign bodies.

OBJECTIVE: To determine the sensitivity and specificity of plain films in differentiating coin batteries from coins.

SETTING: Study was conducted at a tertiary referral university medical center.

METHODS: Eleven radiographs were taken of various objects and independently reviewed by 14 radiologists and otolaryngologists. Reviewers were asked to identify the object filmed as either a battery or not a battery. In addition, otolaryngologists were asked if they would immediately proceed to the operative suite for removal based on the film. Results were tabulated and analyzed using a spreadsheet.

RESULTS: Overall, plain films had a sensitivity and specificity of 80.4% and 79.1%, respectively with an overall accuracy of 79.8%. When used as a test to determine urgency of removal, sensitivity increases to 94.4% while specificity decreases to 67.1% with an overall accuracy of 83.1%.

CONCLUSIONS: Plain films are an effective method of evaluating for the possibility of batteries as esophageal foreign bodies.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app