Risk factors for mesh/suture erosion following sacral colpopexy.
American Journal of Obstetrics and Gynecology 2008 December
OBJECTIVE: The purpose of this study was to identify risks for mesh/suture erosions following abdominal sacral colpopexy (ASC).
STUDY DESIGN: We analyzed demographic, perioperative variables, and erosion status in 322 participants in the Colpopexy and Urinary Reduction Efforts study 2 years after sacral colpopexy.
RESULTS: The predominant graft used was synthetic mesh: woven polyester (Mersilene; Ethicon, Inc, Somerville, NJ) (42%) or polypropylene (48%). Twenty subjects (6%) experienced mesh/suture erosion. Unadjusted risk factors for mesh/suture erosion were expanded polytrafluroethylene (ePTFE) mesh (ePTFE 4/21 [19%] vs non-ePTFE 16/301 [5%]; odds ratio [OR], 4.2), concurrent hysterectomy (OR, 4.9), and current smoking (OR, 5.2). Of those with mesh erosion, most affected women (13/17) underwent at least 1 surgery for partial or total mesh removal. Two were completely resolved, 6 had persistent problems, and 5 were lost to follow-up. No resolution was documented in the 4 women who elected observation.
CONCLUSION: Expanded PTFE mesh should not be used for sacral colpopexy. Concurrent hysterectomy and smoking are modifiable risks for mesh/suture erosion.
STUDY DESIGN: We analyzed demographic, perioperative variables, and erosion status in 322 participants in the Colpopexy and Urinary Reduction Efforts study 2 years after sacral colpopexy.
RESULTS: The predominant graft used was synthetic mesh: woven polyester (Mersilene; Ethicon, Inc, Somerville, NJ) (42%) or polypropylene (48%). Twenty subjects (6%) experienced mesh/suture erosion. Unadjusted risk factors for mesh/suture erosion were expanded polytrafluroethylene (ePTFE) mesh (ePTFE 4/21 [19%] vs non-ePTFE 16/301 [5%]; odds ratio [OR], 4.2), concurrent hysterectomy (OR, 4.9), and current smoking (OR, 5.2). Of those with mesh erosion, most affected women (13/17) underwent at least 1 surgery for partial or total mesh removal. Two were completely resolved, 6 had persistent problems, and 5 were lost to follow-up. No resolution was documented in the 4 women who elected observation.
CONCLUSION: Expanded PTFE mesh should not be used for sacral colpopexy. Concurrent hysterectomy and smoking are modifiable risks for mesh/suture erosion.
Full text links
Related Resources
Trending Papers
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app