COMPARATIVE STUDY
EVALUATION STUDY
JOURNAL ARTICLE
RESEARCH SUPPORT, NON-U.S. GOV'T
Add like
Add dislike
Add to saved papers

Multislice computed tomography in infective endocarditis: comparison with transesophageal echocardiography and intraoperative findings.

OBJECTIVES: The aim of this study was to assess the value of multislice computed tomography (CT) for the assessment of valvular abnormalities in patients with infective endocarditis (IE) in comparison with transesophageal echocardiography (TEE) and intraoperative findings.

BACKGROUND: Multislice CT has recently shown promising data regarding valvular imaging in a 4-dimensional fashion.

METHODS: Thirty-seven consecutive patients with clinically suspected IE were examined with TEE and 64-slice CT or dual-source CT. Twenty-nine patients had definite IE and underwent surgery.

RESULTS: The diagnostic performance of CT for the detection of evident valvular abnormalities for IE compared with TEE was: sensitivity 97%, specificity 88%, positive predictive value (PPV) 97%, and negative predictive value (NPV) 88% on a per-patient basis (n = 37; excellent intermodality agreement kappa = 0.84). CT correctly identified 26 of 27 (96%) patients with valvular vegetations and 9 of 9 (100%) patients with abscesses/pseudoaneurysms compared with the intraoperative specimen. On a per-valve-based analysis, diagnostic accuracy for the detection of vegetations and abscesses/pseudoaneurysms compared with surgery was: sensitivity 96%, specificity 97%, PPV 96%, NPV 97%, and sensitivity 100%, specificity 100%, PPV 100%, NPV 100%, respectively, without significant differences as compared with TEE. Vegetation size measurements by CT correlated (r = 0.95; p <0.001) with TEE (mean 7.6 +/- 5.6 mm). The mobility of vegetations was accurately diagnosed in 21 of 22 (96%) patients with CT, but all of 4 leaflet perforations (<or=2 mm) were missed. CT provided more accurate anatomic information regarding perivalvular extent of abscess/pseudoaneurysms than TEE.

CONCLUSIONS: Multislice CT shows good results in detecting valvular abnormalities in IE and could be applied in pre-operative planning and exclusion of coronary artery disease before surgery.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app