We have located links that may give you full text access.
JOURNAL ARTICLE
RESEARCH SUPPORT, NON-U.S. GOV'T
Test-retest reliability of drug-induced sleep endoscopy.
OBJECTIVE: To determine the test-retest reliability of drug-induced sleep endoscopy (DISE).
METHODS: Prospective cohort study. Patients with OSA underwent two separate DISE examinations. The following outcomes were measured: a global assessment of obstruction at the palate and/or hypopharynx; the degree of obstruction at the palate and hypopharynx; and the contribution of individual structures (palate, tonsils, tongue, epiglottis, and lateral pharyngeal walls) to obstruction.
RESULTS: Thirty-two patients underwent two separate DISE examinations. The preoperative sleep study apnea-hypopnea index was 40.7 +/- 21.1, and the lowest oxygen saturation was 79.8 +/- 17.4 percent. Point estimates for the intraclass correlation coefficient analogs related to palatal obstruction ranged from 0.41 to 0.89; related to the hypopharyngeal airway, the point estimates ranged from 0.57 to 0.84.
CONCLUSION: The test-retest reliability of DISE appears good, especially in the evaluation of the hypopharyngeal airway. Larger studies can generate more precise confidence interval estimates and test the generalizability of these findings.
METHODS: Prospective cohort study. Patients with OSA underwent two separate DISE examinations. The following outcomes were measured: a global assessment of obstruction at the palate and/or hypopharynx; the degree of obstruction at the palate and hypopharynx; and the contribution of individual structures (palate, tonsils, tongue, epiglottis, and lateral pharyngeal walls) to obstruction.
RESULTS: Thirty-two patients underwent two separate DISE examinations. The preoperative sleep study apnea-hypopnea index was 40.7 +/- 21.1, and the lowest oxygen saturation was 79.8 +/- 17.4 percent. Point estimates for the intraclass correlation coefficient analogs related to palatal obstruction ranged from 0.41 to 0.89; related to the hypopharyngeal airway, the point estimates ranged from 0.57 to 0.84.
CONCLUSION: The test-retest reliability of DISE appears good, especially in the evaluation of the hypopharyngeal airway. Larger studies can generate more precise confidence interval estimates and test the generalizability of these findings.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app