Comparative Study
Evaluation Study
Journal Article
Add like
Add dislike
Add to saved papers

Diagnostic accuracy of 64 multidetector computed tomographic angiography in peripheral vascular disease.

BACKGROUND: Previous studies of multidetector CT (MDCT) of the lower extremities for the detection of peripheral vascular disease showed high diagnostic accuracy but were performed with older generation systems.

OBJECTIVE: The purpose of this study was to evaluate the diagnostic accuracy of 64 MDCT for the detection of hemodynamically significant disease within the lower extremity peripheral vasculature as compared to digital subtraction angiography (DSA).

METHODS: Twenty-eight consecutive patients with symptomatic lower extremity intermittent claudication and an abnormal ankle-brachial index (ABI; less than 0.9) were evaluated by both 64 MDCT and DSA. Axial images were acquired with a 64 multidetector general electric light speed VCT scanner. Images were analyzed using a GE Advantage workstation (AW 4.3) capable of advanced image processing and manipulation. The aorto-iliac and lower extremity arteries were divided into 15 segments per limb (30 segments per patient). Eight hundred forty segments were analyzed in a blinded fashion by physicians with level III CT certification. Segments were classified as grade I (<10% stenosis), grade II (10-49%), grade III (50-99%), and grade IV (occlusion).

RESULTS: For all segments evaluated, the overall diagnostic accuracy for detecting grade III and IV lesions was 98% with a sensitivity of 99% and a specificity of 98%. For the aorto-iliac segments, the diagnostic accuracy was 98% with a sensitivity of 100% and a specificity of 99%. For the femoro-popliteal segments, the overall accuracy was 98% with a sensitivity of 100% and a specificity of 99%. For the infra-popliteal segments, the overall accuracy was 98% with a sensitivity of 97% and a specificity of 99%. One segment could not be visualized by MDCT compared to 49 segments that could not be visualized by DSA.

CONCLUSIONS: This study demonstrates excellent diagnostic accuracy of 64 MDCT in the detection of hemodynamically significant disease of the lower extremities. More segments are visualized using 64 MDCT than DSA, allowing more complete visualization of the vascular tree. CT angiography should be considered in the diagnostic evaluation of symptomatic patients with peripheral vascular disease.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app