We have located links that may give you full text access.
Clinical Trial
Journal Article
Research Support, N.I.H., Extramural
Research Support, Non-U.S. Gov't
Prepuncture ultrasound imaging to predict transverse process and lumbar plexus depth for psoas compartment block and perineural catheter insertion: a prospective, observational study.
Anesthesia and Analgesia 2010 June 2
BACKGROUND: All widely used psoas compartment block/catheter techniques have a common limitation: external landmarks do not accurately predict lumbar plexus depth, leaving practitioners to "guess" at what depth to stop advancing the placement needle when neither transverse process nor lumbar plexus is intercepted. We assessed the accuracy of ultrasound in estimating transverse process depth before needle insertion and prediction of actual needle-to-plexus intercept depth for psoas compartment nerve blocks and perineural catheter insertion.
METHODS: Before needle insertion, ultrasound was used to estimate the depth of the transverse process lying directly anterior to the intercrestal line. If a transverse process was not directly anterior to the intercrestal line, then the process immediately caudad to the line was imaged. The ultrasound transducer remained in the parasagittal plane, perpendicular to the skin. After this measurement, the transducer was removed, an insulated needle connected to a nerve stimulator inserted in the parasagittal plane, and the depth of both the transverse process (if contacted) and lumbar plexus noted. A perineural catheter was subsequently inserted.
RESULTS: Of 53 enrolled subjects, in 50 cases (94%), the transverse processes were identified by ultrasound at a median (interquartile; range) depth of 5.0 cm (4.5-5.5 cm; 3.5-7.5 cm). In 27 subjects (54%), a transverse process was positioned directly anterior to the intercrestal line, and in all of these subjects, the transverse process was intercepted with the block needle a median of 0.5 cm (0.0-1.0 cm; 0.0-1.0 cm) within the predicted depth. In all 50 subjects in whom the transverse processes were identified by ultrasound, the actual lumbar plexus depth measured with the needle was a median of 7.5 cm (7.0-8.5 cm; 5.0-9.5 cm), and the plexus depth was a median of 2.5 cm (2.0-3.0 cm; 0.2-4.0 cm) past the estimated transverse process depth by ultrasound. By ultrasound, the intersection of the middle and lateral thirds of the intercrestal line between the midline and a parallel line through the posterosuperior iliac spine was too lateral to permit needle-transverse process contact in 50% of the subjects. However, moving the transducer 0.75 cm toward the midline allowed for transverse process imaging in all subjects.
CONCLUSIONS: For psoas compartment blocks/catheters, prepuncture ultrasound imaging accurately predicts transverse process depth to within 1 cm, and if the lumbar plexus is estimated to be within 3 cm of the transverse process, ultrasound allows prediction of maximal lumbar plexus depth to within 1 cm.
METHODS: Before needle insertion, ultrasound was used to estimate the depth of the transverse process lying directly anterior to the intercrestal line. If a transverse process was not directly anterior to the intercrestal line, then the process immediately caudad to the line was imaged. The ultrasound transducer remained in the parasagittal plane, perpendicular to the skin. After this measurement, the transducer was removed, an insulated needle connected to a nerve stimulator inserted in the parasagittal plane, and the depth of both the transverse process (if contacted) and lumbar plexus noted. A perineural catheter was subsequently inserted.
RESULTS: Of 53 enrolled subjects, in 50 cases (94%), the transverse processes were identified by ultrasound at a median (interquartile; range) depth of 5.0 cm (4.5-5.5 cm; 3.5-7.5 cm). In 27 subjects (54%), a transverse process was positioned directly anterior to the intercrestal line, and in all of these subjects, the transverse process was intercepted with the block needle a median of 0.5 cm (0.0-1.0 cm; 0.0-1.0 cm) within the predicted depth. In all 50 subjects in whom the transverse processes were identified by ultrasound, the actual lumbar plexus depth measured with the needle was a median of 7.5 cm (7.0-8.5 cm; 5.0-9.5 cm), and the plexus depth was a median of 2.5 cm (2.0-3.0 cm; 0.2-4.0 cm) past the estimated transverse process depth by ultrasound. By ultrasound, the intersection of the middle and lateral thirds of the intercrestal line between the midline and a parallel line through the posterosuperior iliac spine was too lateral to permit needle-transverse process contact in 50% of the subjects. However, moving the transducer 0.75 cm toward the midline allowed for transverse process imaging in all subjects.
CONCLUSIONS: For psoas compartment blocks/catheters, prepuncture ultrasound imaging accurately predicts transverse process depth to within 1 cm, and if the lumbar plexus is estimated to be within 3 cm of the transverse process, ultrasound allows prediction of maximal lumbar plexus depth to within 1 cm.
Full text links
Related Resources
Trending Papers
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Prevention and treatment of ischaemic and haemorrhagic stroke in people with diabetes mellitus: a focus on glucose control and comorbidities.Diabetologia 2024 April 17
Diagnosis and Management of Cardiac Sarcoidosis: A Scientific Statement From the American Heart Association.Circulation 2024 April 19
Eosinophilic Esophagitis: Clinical Pearls for Primary Care Providers and Gastroenterologists.Mayo Clinic Proceedings 2024 April
Essential thrombocythaemia: A contemporary approach with new drugs on the horizon.British Journal of Haematology 2024 April 9
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app