Topography-guided conductive keratoplasty: treatment for advanced keratoconus.
American Journal of Ophthalmology 2010 October
PURPOSE: To evaluate the use of topography-guided conductive keratoplasty in eyes with keratoconus.
DESIGN: Interventional case series.
METHODS: We examined 21 eyes in 21 patients with advanced keratoconus. Topography-guided conductive keratoplasty was performed with intraoperative monitoring of corneal astigmatism using a surgical keratometer. Uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), corneal topography, manifest refraction, intraocular pressure (IOP), corneal endothelial cell counts, complications, and eventual outcomes were evaluated.
RESULTS: UCVA (logarithm of the minimal angle of resolution [logMAR]), which was 1.65 ± 0.49 preoperatively, improved to 1.04 ± 0.64 at 1 week (P < .001) and 1.12 ± 0.61 at 1 month after surgery (P < .001). BSCVA, which was 1.02 ± 0.56 preoperatively, improved to 0.76 ± 0.65 at 1 week (P = .026) and 0.76 ± 0.60 at 1 month after surgery (P = .003). Manifest refraction, which was -15.13 ± 6.66 diopters (D) before surgery, declined to -9.97 ± 6.71 D at 1 month after surgery (P = .002). Although corneal topography reverted to the preoperative pattern and UCVA and BSCVA also regressed toward preoperative values, 12 of 21 eyes were better able to tolerate and conduct normal daily activities using contact lenses. Five subjects have undergone or are considering corneal transplantation after unsatisfactory postoperative results. No serious perioperative complication was observed.
CONCLUSIONS: Topography-guided conductive keratoplasty may be effective in reshaping corneal configuration in eyes with keratoconus, without serious complications, and possibly contributed to avoiding or delaying corneal transplantation.
DESIGN: Interventional case series.
METHODS: We examined 21 eyes in 21 patients with advanced keratoconus. Topography-guided conductive keratoplasty was performed with intraoperative monitoring of corneal astigmatism using a surgical keratometer. Uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), corneal topography, manifest refraction, intraocular pressure (IOP), corneal endothelial cell counts, complications, and eventual outcomes were evaluated.
RESULTS: UCVA (logarithm of the minimal angle of resolution [logMAR]), which was 1.65 ± 0.49 preoperatively, improved to 1.04 ± 0.64 at 1 week (P < .001) and 1.12 ± 0.61 at 1 month after surgery (P < .001). BSCVA, which was 1.02 ± 0.56 preoperatively, improved to 0.76 ± 0.65 at 1 week (P = .026) and 0.76 ± 0.60 at 1 month after surgery (P = .003). Manifest refraction, which was -15.13 ± 6.66 diopters (D) before surgery, declined to -9.97 ± 6.71 D at 1 month after surgery (P = .002). Although corneal topography reverted to the preoperative pattern and UCVA and BSCVA also regressed toward preoperative values, 12 of 21 eyes were better able to tolerate and conduct normal daily activities using contact lenses. Five subjects have undergone or are considering corneal transplantation after unsatisfactory postoperative results. No serious perioperative complication was observed.
CONCLUSIONS: Topography-guided conductive keratoplasty may be effective in reshaping corneal configuration in eyes with keratoconus, without serious complications, and possibly contributed to avoiding or delaying corneal transplantation.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app