We have located links that may give you full text access.
Journal Article
Randomized Controlled Trial
Short- vs long-axis approach to ultrasound-guided peripheral intravenous access: a prospective randomized study.
American Journal of Emergency Medicine 2011 November
OBJECTIVE: The objective of the study was to determine if the short-axis approach and long-axis approach to ultrasound-guided peripheral intravenous access (USGPIV) differ in success rate, catheter insertion time, and number of needle sticks.
METHODS: A convenience sample of emergency department patients aged 18 to 65 years with difficult IV access (2 or more failed landmark attempts) was prospectively randomized to short-axis or long-axis USGPIV. Time from skin puncture to catheter insertion (insertion time) and number of needle sticks were recorded. Number of needle sticks and insertion time were compared using Mann-Whitney U tests.
RESULTS: Forty subjects were enrolled; 20 were randomized to the short-axis and 20 to the long-axis approach. Success rate was 95% (19/20; 95% confidence interval, 85%-100%) in the short-axis group compared with 85% (17/20; 95% confidence interval, 69%-100%) in the long-axis group. All 3 subjects with failed IV placement in the long-axis group had successful rescue USGPIV placement in short axis. Median insertion time was 34 seconds (interquartile range, 35 seconds) for the short-axis group compared with 91 seconds (interquartile range, 59 seconds) for the long-axis group (P = .02). Mean number of needle sticks was 1.5 (±SD 0.7) in the short-axis group compared with 1.4 (±SD 0.7) in the long-axis group (P = .82).
CONCLUSIONS: Short-axis USGPIV technique required less insertion time than the long-axis technique. Success rate was higher in the short-axis group, but this difference was not statistically significant. However, all of the failed IVs in the long axis were rescued successfully in short axis.
METHODS: A convenience sample of emergency department patients aged 18 to 65 years with difficult IV access (2 or more failed landmark attempts) was prospectively randomized to short-axis or long-axis USGPIV. Time from skin puncture to catheter insertion (insertion time) and number of needle sticks were recorded. Number of needle sticks and insertion time were compared using Mann-Whitney U tests.
RESULTS: Forty subjects were enrolled; 20 were randomized to the short-axis and 20 to the long-axis approach. Success rate was 95% (19/20; 95% confidence interval, 85%-100%) in the short-axis group compared with 85% (17/20; 95% confidence interval, 69%-100%) in the long-axis group. All 3 subjects with failed IV placement in the long-axis group had successful rescue USGPIV placement in short axis. Median insertion time was 34 seconds (interquartile range, 35 seconds) for the short-axis group compared with 91 seconds (interquartile range, 59 seconds) for the long-axis group (P = .02). Mean number of needle sticks was 1.5 (±SD 0.7) in the short-axis group compared with 1.4 (±SD 0.7) in the long-axis group (P = .82).
CONCLUSIONS: Short-axis USGPIV technique required less insertion time than the long-axis technique. Success rate was higher in the short-axis group, but this difference was not statistically significant. However, all of the failed IVs in the long axis were rescued successfully in short axis.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app