Comparative Study
Journal Article
Add like
Add dislike
Add to saved papers

Impact of lesion sets on mid-term results of surgical ablation procedure for atrial fibrillation.

OBJECTIVES: The objective of this study was to evaluate the effects of different lesion sets of ablation in patients undergoing mitral surgery plus maze.

BACKGROUND: The role of lesion sets on outcome after maze is poorly defined.

METHODS: A total of 141 patients were prospectively followed up. Two different lesion sets were prepared: 32 patients underwent a radiofrequency left atrial lesion set of maze ("limited"), and 109 had combined left and right atrial lesion sets of maze ± ganglionic plexi isolation ("extensive"). A longitudinal observational study assessed the role of "extensive" versus "limited" ablation on atrial fibrillation (AF), New York Heart Association (NYHA) functional class II/III, treatment with antiarrhythmic drugs, follow-up recovery of the ratio of E- to A-wave (E/A), and survival and time to hospitalization (overall and for heart failure).

RESULTS: The prevalence of AF over time was lower in the "extensive" arm (adjusted relative risk [RR]: 0.10; 95% confidence interval [CI]: 0.03 to 0.31; p < 0.001), with significantly lower prevalence at discharge, 3 months, and 18 months. The prevalence of patients in NYHA functional class II/III over time was lower in the "extensive" arm (adjusted RR: 0.11; 95% CI: 0.03 to 0.34; p < 0.001), with significant differences at any assessment (except the third month). The differences in E/A recovery and use of antiarrhythmic drugs were less marked, with an RR of 1.55 (95% CI: 0.99 to 2.42; p = 0.05) and RR of 0.76 (95% CI: 0.54 to 1.06; p = 0.11), respectively, with a significantly lower prevalence of antiarrhythmic drugs in the "extensive" ablation arm at 12, 18, and 24 months. Rates of hospitalization for heart failure, overall hospitalization, and the combined event death/hospitalization were lower in the "extensive" arm (p = 0.11, p = 0.003, and p = 0.002, respectively).

CONCLUSIONS: The addition of right-sided ablation improves clinical and electrophysiologic results after maze procedure.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app